indoor and outdoor carbon monoxide(co) concentrations at hospital kitchens

نویسندگان

mahmoud mohammadyan associated professor, health sciences research center, faculty of health, mazandaran university of medical sciences, sari, iran

behzad heibati health sciences research center, faculty of health, mazandaran university of medical sciences, sari, iran

maryam mostafaee department of environmental pollution, school of environment and energy, science and research branch, islamic azad university, tehran, iran

narges ghorbani department of biostatistics, faculty of health, mazandaran university of medical sciences, sari, iran

چکیده

carbon monoxide (co) poisoning is one of the most common causes of death in iran. the present study investigated the indoor and outdoor co concentrations at hospitals under the supervision of mazandaran university of medical sciences in sari, iran.indoor and outdoor measured co were conducted over a period of one month during the 2012 winter season in 4 hospital kitchens using a direct measurement device specialized for co. the average concentrations of co gas through gas measuring stations were considered at three stations both in and out of the kitchens.the highest and the lowest average concentrations of outdoor co in fatemeh zahra hospital (about 2 ppm) and zare hospital (about 0.33 ppm) were measured respectively. besides, the highest and the lowest average concentrations of indoor co were detected in imam hospital (as 9.66 ppm) and buali hospital (as7.66 ppm). the highest ratios of i/o (approximately 10 ppm) have been conducted between 8:00 and 9:00a.m. the lowest median concentrations of co (approximately 8 ppm) between 11:00 and 12:00 a.m. have been measured. concentrations of co in all hospitals in this study were significant.this fact shows poorly ventilation of kitchen due to lack of ventilation design engineering.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of indoor and outdoor radon concentrations during Superstorm Sandy.

Superstorm Sandy affected much of the US East Coast extending over 1800 km. It passed over the test location in the State of Maryland on 29 October 2012. Being 350 km away from the regions of highest intensity the storm was of lower intensity at the test location. Continuous radon monitors and passive radon monitors were used for the measurement. The test location was the basement of a single f...

متن کامل

Patients satisfactory from outdoor and indoor environments of a training hospital

Respect to the design guidelines of building environments is a complex subject that associated with cultural and economic development of human societies. Therefore, accurately measuring users’ favorites for environment design is a essential subject to optimize the relationship between environmental and personal parameters. This study with the purpose of investigation of patients satisfactory fr...

متن کامل

کیفیت هوای آشپزخانه رستورانهای بخشی ازجنوب شهر تهران بزرگ در سال 1385

  Background and aims   Generally nitrogen dioxide (NO 2 ) and carbon monoxide (CO) are emitted Toxic gases like carbon monoxide (CO.), carbon dioxide (CO 2 ), nitrogen oxides (NOx) will remain in the kitchen when cooking with a gas stove. The purpose of the present study was to measure carbon monoxide (CO) and nitrogen dioxide (NO 2 ) levels during the operation of cooking  in restaurant kitch...

متن کامل

Indoor and Outdoor Air Quality of Poultry Farm at Bangalore

The present study was to determine the concentration, in terms of monthly and seasonal distribution and in relation to meteorological factors, of indoor and outdoor airborne fungal spores in poultry farm at Bangalore. Samples were collected at fortnightly for a period of one year in duplicates between January 2011 to December 2011 by using Andersen two stage viable air sampler petri plates cont...

متن کامل

Indoor Carbon Dioxide Concentrations and Sbs in Office Workers

Relationships between indoor carbon dioxide (CO2) levels and mucous membrane and lower respiratory sick building syndrome (SBS) symptoms are explored in 41 office buildings from the US EPA BASE study. Elevated indoor CO2 concentrations may indicate inadequate ventilation per occupant and elevated indoor pollutant concentrations, leading to SBS symptoms. Two CO2 metrics were constructed: average...

متن کامل

Indoor-Outdoor Image Classification

We show how high-level scene properties can be inferred from classiication of low-level image features, speciically for the indoor-outdoor scene retrieval problem. We systematically studied the features: (1) his-tograms in the Ohta color space (2) multiresolution, simultaneous autoregressive model parameters (3) coef-cients of a shift-invariant DCT. We demonstrate that performance is improved b...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
international journal of occupational hygiene

جلد ۷، شماره ۲، صفحات ۹۸-۱۰۴

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023