intra-observer and inter-observer reliability in direct

نویسندگان

naser hashemi-nejad department of occupational health, school of public health, kerman university of medical sciences, kerman, iran.

alireza choobineh professor of occupational health, ergonomics department, school of health and nutrition, research center for health sciences, shiraz university of medical sciences, shiraz, iran.

mohammadreza baneshi phd in biostatistics, research center for modeling in health, institute for futures studies in health, kerman university of medical sciences, kerman, iran.

akram jafari-roodbandi msc student of occupational health, member of kerman medical student research committee, kerman university of medical sciences, kerman, iran.

چکیده

this study aimed to evaluate the reliability factors, and identify causes of error in direct anthropometry method. after training three beginner anthropometrists and following the instructions of anthropometric standards, 48 body dimensions of 42 male students were measured three times. in other words, the physical dimensions of each subject were measured for 9 times. all participants were wearing uniforms during anthropometry, with bare feet. differences in values of repeated measurement test were explored using spss software version 11. the same software was employed to evaluate, through calculating icc index, the correlation between anthropometrists. inter-observer repeated measurement test showed significant difference in the measurements taken in 3, 7 and 1 dimension(s) by the three anthropometrists. the average measurement was significantly different at 16 dimensions; this, however, showed no difference at 32 dimensions. measurements taken by anthropometrist 1 had icc values of 0.26 (min) and 0.99 (max)  these values were 0.48 (min) and 1.00 (max) for anthropometrist 2 and 0.23 (min) and 0.98 (max) for antropometrist 3. the maximum and minimum values of icc index in all three anthropometrists were respectively close to and above 0.98, and lower than 0.5. high value of icc in the measured dimensions indicated high reliability of repeated measurements. the decreasing value of some indexes can be attributed to such factors as random error, poor design of measurements tool (which in turn leads to random error), the long time devoted to measurement process, high number of dimension measured, changes in posture of subjects and deviation from the standard position.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter - Observer Reliability

Just as scientific records can be vulnerable to variation between different pieces of recording equipment, so observational records are subject to differences in how observers score behaviour. However one can judge how much confidence to place in one's results by assessing the reliability of the records of one's variables. In this paper we shall consider only inter-observer reliability or score...

متن کامل

Inter-observer reliability and intra-observer reproducibility of the Weber classification of ankle fractures.

Our aim was to assess the reproducibility and the reliability of the Weber classification system for fractures of the ankle based on anteroposterior and lateral radiographs. Five observers with varying clinical experience reviewed 50 sets of blinded radiographs. The same observers reviewed the same radiographs again after an interval of four weeks. Inter- and intra-observer agreement was assess...

متن کامل

Intra-observer, inter-observer and inter-scanner variations in brain MRI volume measurements in multiple sclerosis.

INTRODUCTION Measurement of brain volume on magnetic resonance imaging (MRI) scans is regarded as an objective marker of multiple sclerosis (MS) severity with the potential to monitor treatment efficacy accurately. This study was performed to assess the variability of brain MRI volume measurements. PATIENTS AND METHODS We studied nine patients with relapsing-remitting MS, who were imaged on t...

متن کامل

Intra-observer and inter-observer reliability of leg circumference measurement among six observers: a single blinded randomized trial

Hypothesis: Circumference measurement of extremities that was reported to be a reliable method as long as being standardized is commonly used both in clinical and home settings by clinicians or caregivers due to its cheapness and easy use. Objectives: The aims of this study were to determine the inter-observer and intra-observer reliability of manual circumference measurement among different ob...

متن کامل

Inter-observer and intra-observer variability in immunohistochemical detection of endometrial stromal plasmacytes in chronic endometritis

Chronic endometritis (CE) is an unusual endometrial inflammation characterized by stromal plasmacyte infiltration. CE is easily missed due to its subtle symptoms and demanding histopathological examinations. Although the immunohistochemistry for the plasmacyte marker CD138 has facilitated the detection of endometrial stromal plasmacytes, the accuracy and biases of this method for CE diagnosis r...

متن کامل

Intra-observer and inter-observer repeatability of ocular surface interferometer in measuring lipid layer thickness

BACKGROUND Tear lipid morphology is important for normal tear function. Recently, there have been clinical studies using interferometry to assess lipid layer thickness (LLT). The aim of the study is to examine the repeatability of a commercially available interferometer. METHODS Two observers measured LLT in twenty Asian subjects (20 eyes) using an interferometer (LipiView® ocular surface int...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
international journal of occupational hygiene

جلد ۵، شماره ۲، صفحات ۸۲-۸۸

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023