the hp-version of finite element method for electrical impedance tomography with eidors

نویسندگان
چکیده

in this study, focuses on applying the hp-version for forward modeling. the eit forward solver is normally based on the conventional finite element method (hfem). in h-fem, the polynomial order p of the element shape functions is constant and the element size h, is decreased. to accurately simulate the forward solution with the hfem, a mesh with large number of nodes and elements is usually needed. to overcome this problem, we proposed the high order finite element method for eit forward problem. in the p-version, the polynomial order is increased and the mesh size is constant. combinations of refine the mesh adaptively and used higher order polynomials are called hp-extensions (hp-fem). with the high order fem, a smaller number of nodes and hence less computational time and memory are needed to achieve the same or better accuracy in the forward solution than the hfem. numerical results are presented that the performance of the hp-version is better than of the h-version.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison between the hp-version of Finite Element Method with EIDORS for Electrical Impedance Tomography

In this study, a hp-version of Finite Element Method (FEM) was applied for forward modeling in image reconstruction of Electrical Impedance Tomography (EIT). The EIT forward solver is normally based on the conventional Finite Element Method (h-FEM). In h-FEM, the polynomial order (p) of the element shape functions is constant and the element size (h) is decreasing. To have an accurate simulatio...

متن کامل

A High-order Finite Element Method for Electrical Impedance Tomography

Electrical impedance tomography (EIT) is a non-invasive imaging technique where a conductivity distribution in a domain is reconstructed from boundary voltage measurements. The voltage data are generated by injecting currents into the domain. This is an ill-conditioned non-linear inverse problem. Small measurement or forward modeling errors can lead to unbounded fluctuations in the reconstructi...

متن کامل

Electrical impedance tomography of human brain function using reconstruction algorithms based on the finite element method.

Electrical impedance tomography (EIT) is a recently developed technique which enables the internal conductivity of an object to be imaged using rings of external electrodes. In a recent study, EIT during cortical evoked responses showed encouraging changes in the raw impedance measurements, but reconstructed images were noisy. A simplified reconstruction algorithm was used which modelled the he...

متن کامل

Applications of Electrical Impedance Tomography in Neurology

Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...

متن کامل

On applying stochastic Galerkin finite element method to electrical impedance tomography

Aalto University, P.O. Box 11000, FI-00076 Aalto www.aalto.fi Author Matti Leinonen Name of the doctoral dissertation On applying stochastic Galerkin finite element method to electrical impedance tomography Publisher School of Science Unit Department of Mathematics and Systems Analysis Series Aalto University publication series DOCTORAL DISSERTATIONS 135/2015 Field of research Mathematics Manus...

متن کامل

A method for rapid production of subject specific finite element meshes for electrical impedance tomography of the human head.

Finite element (FE) methods are widely used in electrical impedance tomography (EIT) to enable rapid image reconstruction of different tissues based on their electrical conductivity. For EIT of brain function, anatomically-accurate (head-shaped) FE meshes have been shown to improve the quality of the reconstructed images. Unfortunately, given the lack of a computational protocol to generate pat...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of medical signals and sensors

جلد ۱، شماره ۳، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023