application of sybr-green real time rt-pcr for quantification of human immunodeficiency virus type-1 (hiv-1) and comparison with cobas amplicor test

نویسندگان

saeid amel jamehdar

farzaneh sabahi

mahdi forouzandeh

mahboubeh haji abdolbaghi

anooshiravan kazemnejad

چکیده

objective: in this study, a sybr green real-time rt-pcr assay for quantification of hiv-1 viral rna was developed. materials and methods: this assay was performed based on amplification of the pol region of hiv-1 and product analysis by an abi 7500 system. we quantified hiv-1 viral load in 26 seropositive patients by this system and the data were subsequently compared with results obtained with a reference technique represented by cobas amplicor hiv-1 monitor test. results: the results demonstrated that this technique could detecte up to 500 hiv-1 rna copies/ml of plasma. the linearity of this approach was conserved over a wide range of hiv-1 copy numbers (5×102-5×109). since no positive signal was observed in seronegative volunteers, the specificity of the test was calculated as 100%. comparison of the results with those obtained by the reference quantification method, revealed a significant correlation between the results (r2= 0.95). conclusion: on the basis of the most recent recorded cases for hiv-1 infection and aids in iran, the prevalence of this disease is rising rapidly and the situation has been called to be alarming by national health representatives. determination of hiv-1 viral load in plasma has been considered as the most effective single prediction tool of clinical outcome. indeed, the development and stabilization of hiv-1 rna assays have given physicians a unique tool for monitoring hiv-1 patients treated with antiviral drugs. in this study, we have developed a sybr-green real time rt-pcr assay for quantitative analysis of hiv-1 in infected patients. since a synthetic rna standard was used in this assay, the upper limit of detection was detected to be higher than the standard test (5×10 9 versus 7.5×10 5). this can be important in patients with acute high viral load infections. reproducibility was assessed by intra assay and inter assay analysis. coefficient of variations ct, in reproducibility tests for intra assay and inter assay variability were less than

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design a Real Time PCR with SYBR Green for quantification of HTLV-1 proviral load for blood donors

Abstract Background and Objectives In Iran, Khorasan province is an endemic area for HTLV-1 virus. Considering the inability of serological tests to determine HTLV-1 in window period, their failure to confirm the indetermination results of western blot, and given the probability for HTLV-1 transfusion transmission, a SYBR green-based Real Time PCR was set to measure the HTLV-1 proviral load.  ...

متن کامل

Quantification Analysis of Dot Blot Assays for Human Immunodeficiency Virus Type 1 and 2 Antibodies

Objective Dot Blot (DB) assay provides highly specific results, but usually not reliable for quantification of antibody production. The need for a more objective DB assay to provide a better definition of the immune status, against HIV antigens, promoted this study to be done to develop a quantitative DB assay. Material and Methods Dot blot (DB) strips for antibodies directed to human immuno...

متن کامل

Development of SYBR Green I Based Real-Time RT-PCR Assay for Specific Detection of Watermelon silver mottle Virus

Background: Watermelon silver mottle virus (WSMoV), which belongs to the genus Tospovirus, causes significant loss in Cucurbitaceae plants. Objectives: Development of a highly sensitive and reliable detection method for WSMoV. Materials and Methods: Recombinant plasmids for targeting the sequence of nucleocapsid protein gene of WSMoV were constructed. SYBR Green I real-time PCR was established...

متن کامل

Analytical Performances of Human Immunodeficiency Virus Type 1 RNA-Based Amplix® Real-Time PCR Platform for HIV-1 RNA Quantification

Objectives. We evaluated the performances of Amplix real-time PCR platform developed by Biosynex (Strasbourg, France), combining automated station extraction (Amplix station 16 Dx) and real-time PCR (Amplix NG), for quantifying plasma HIV-1 RNA by lyophilized HIV-1 RNA-based Amplix reagents targeting gag and LTR, using samples from HIV-1-infected adults from Central African Republic. Results. A...

متن کامل

Introducing a New SYBR green Real-time PCR for Detection of SARS-CoV2 Virus Genome

Background and purpose: There are various methods for molecular detection of SARS-CoV2 genome among which, PCR-based methods are the most reliable for making diagnosis. The majority of approved PCR kits for detection of Coronavirus are based on TaqMan real-time PCR which is expensive due to incorporating fluorescent and quencher-harboring probe. The aim of this study was to design a simple and ...

متن کامل

Comparison of the Abbott realtime human immunodeficiency virus type 1 (HIV-1) assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 test: workflow, reliability, and direct costs.

The Abbott RealTime human immunodeficiency virus type 1 (HIV-1) assay (ART) and the Cobas AmpliPrep/Cobas TaqMan HIV-1 test (CTM) are commercially available assays for quantification of HIV-1 RNA in plasma. We evaluated performance characteristics, workflow, throughput, reliability, and direct costs of these assays. Both assays yielded good correlation of quantitative results (r = 0.95) among c...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
modares journal of medical sciences: pathobiology

ناشر: tarbiat modares university

ISSN 1562-9554

دوره 10

شماره Summer 2008 2007

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023