verification of treatment planning system using imsure qa software in non-reference condition

نویسندگان

s r mahdavi

k keshavarzi

e davani

چکیده

objectives: the aim of this study was to verify the treatment planning systems (tpss). the next aim was to validate imsure qa software for patient-specific qa in radiotherapy clinics.  material and methods: we used imsure qa software (standard imaging, v 3.5) for verification of 92 non-imrt plans (540 fields) in 10 radiotherapy clinics. to validate the imsure, dose measurement was performed in cirs phantom. then, imsure calculations were compared with dose measurements. finally, 92 patient plans (540 fields) were re-calculated including abdomen-pelvic, head & neck, breast & chest treatment sites.  results: imsure shows good agreement with dose measurements in the phantom. in the analysis of 540 fields, the mean difference of dose between imsure and tps was 0.62% (~3% sd) and for mu calculation was 1.5% (5.5% sd). per site-treatment analysis shows mean differences of mu for abdomen-pelvic, head & neck, breast & chest treatments 1.3%(5.35% sd), 0.52%(5.22% sd) and 2.5% (7.13%sd), respectively. in addition, it was found that among different treatment planning systems, aaa algorithm has the best agreement with imsure in mean difference of 0.68% for mu and 1.33% for total dose. conclusion: our results show that imsure can be a suitable tool for routine and patient-specific qa, especially when a treatment plan is complex. based on our results, we suggest re-assessment of agreement criteria for chest site treatment.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Verification of Monitor unit calculations for eclipse Treatment Planning System by in- house developed spreadsheet

Introduction: Computerized treatment planning is a rapidly evolving modality that depends on hardware and software efficiency. Despite ICRU recommendations suggesting 5% deviation in dose delivery the overall uncertainty shall be less than 3.5% as suggested by B.J. Minjnheer. J. In house spreadsheets are developed by the medical physicists to cross-verify the dose calculated by the Treatment Pl...

متن کامل

Validation of treatment planning system using simulation PRIMO code.

Introduction: In radiation therapy, in order to double-check the dosimetric results of the main treatment planning system (TPS), a distinct TPS, with few capacitances in terms of contouring and a variety of dose calculation algorithms is used. This system has the capability to double check the planification and the accurate prediction of dose distribution in order to be ensured...

متن کامل

The Erasmus MC Prostate Treatment Planning QA dataset, for evaluation of treatment planning QA models

IMRT treatment planning with commercial treatment planning systems is a trial-and-error process, based on a series of subjective human decisions. Therefore the quality of the IMRT treatment plans may not be consistent among patients, planners or institutions with different experience. Different plan quality assurance (QA) models have been proposed recently, that could flag suboptimal plans that...

متن کامل

automatic verification of authentication protocols using genetic programming

implicit and unobserved errors and vulnerabilities issues usually arise in cryptographic protocols and especially in authentication protocols. this may enable an attacker to make serious damages to the desired system, such as having the access to or changing secret documents, interfering in bank transactions, having access to users’ accounts, or may be having the control all over the syste...

15 صفحه اول

CT-Based Brachytherapy Treatment Planning using Monte Carlo Simulation Aided by an Interface Software

Introduction: In brachytherapy, radioactive sources are placed close to the tumor, therefore, small changes in their positions can cause large changes in the dose distribution. This emphasizes the need for computerized treatment planning. The usual method for treatment planning of cervix brachytherapy uses conventional radiographs in the Manchester system. Nowadays, because of their advantages ...

متن کامل

Point Dose Measurement for Verification of Treatment Planning System using an Indigenous Heterogeneous Pelvis Phantom for Clarkson, Convolution, Superposition, and Fast Superposition Algorithms

Background: Nowadays, advanced radiotherapy equipment includes algorithms to calculate dose. The verification of the calculated doses is important to achieve accurate results. Mostly homogeneous dosimetric phantoms are available commercially which do not mimic the actual patient anatomy; therefore, an indigenous heterogeneous pelvic phantom mimicking actual human pelvic region has been used to ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of biomedical physics and engineering

جلد ۲۰۱۲، شماره ۱۲، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023