investigation of the entrance surface dose and dose to different organs in lumbar spine imaging

نویسندگان

s sina radiation research center, shiraz university, shiraz, iran

b zeinali

m karimipoorfard

f lotfalizadeh

چکیده

background: dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology. objective: the aim of this study is to obtain the entrance skin dose (esd) of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters tld-100 (lif: mg, ti) and gr-200 (lif: mg, cu, p) and also to obtain the absorbed dose to different organs in lumbar spine imaging with several views. methods: to measure the esd values of the patients undergoing lumbar spine imaging, the two tld types were put on their skin surface. the esd values for different views of lumbar spine imaging were also measured by putting the tlds at the surface of the rando phantom. several tld chips were inserted inside different organs of rando phantom to measure the absorbed dose to different organs in lumbar spine imaging. results: the results indicate that there is a close agreement between the results of the two dosimeters. based on the results of this experiment, the esd dose of the 16 patients included in this study varied between 2.71 mgy and 26.29 mgy with the average of 11.89 mgy for tld-100, and between 2.55 mgy and 27.41 mgy with the average of 12.32 mgy for gr-200 measurements. the esds obtained by putting the two types of tlds at the surface of rando phantom are in close agreement. conclusion: according to the results, the gr200 has greater sensitivity than the tld-100.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of the Entrance Surface Dose and Dose to Different Organs in Lumbar Spine Imaging

Background: Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology.Objective: The aim of this study is to obtain the Entrance Skin Dose (ESD) of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti) and GR-200 (LiF: Mg, Cu, P) and also to obtain the ab...

متن کامل

Investigation of the Entrance Surface Dose and Dose to Different Organs in Lumbar Spine Imaging

BACKGROUND Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology. OBJECTIVE The aim of this study is to obtain the Entrance Skin Dose (ESD) of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti) and GR-200 (LiF: Mg, Cu, P) and also to obtain the a...

متن کامل

Effects of Kilovoltage on Image Quality and Entrance Surface Dose in Lumbar Spine Digital Radiography

Introduction: Digital radiography possesses a wide dynamic range and has a major advantage in producing an acceptable image of diagnostic value even though overexposure occurs. Lumbar spine (LS) radiography is the most common examinations that gives high radiation dose to patients and accounts for the highest collective population dose of any conventional radiographic ...

متن کامل

Evaluation of the Entrance Surface Dose (ESD) and Radiation Dose to the Radiosensitive Organs in Pediatric Pelvic Radiography

Background Patients' dosimetry is crucial in order to enhance radiation protection optimization and to deliver low radiation dose to the patients in a radiological procedure. The aim of this study was to assess the entrance surface dose (ESD) and radiation dose to the radiosensitive organs in pediatric pelvic radiography. Materials and Methods The studied population included 98 pediatric patien...

متن کامل

Average Glandular Dose and Entrance Surface Dose in Mammography

In general, dose evaluation for mammography uses average glandular dose (AGD). In mammography, entrance surface dose (ESD) is high, which is well known, but actual clinical data of ESD are not reported so much. This study investigated AGD and ESD for patients whose doses were estimated from 200 mammography examinations using European Organization for Quality-Assured Breast Screening and Diagnos...

متن کامل

Image Quality and Entrance Surface Dose Evaluation of Lateral Cervical Spine: A Study Using Grid and Non-Grid Techniques

Introduction: The purpose of this study is to investigate the effects of grid and non-grid techniques in the lateral cervical spine radiography on image quality and entrance surface dose (ESD). Although image quality and radiation doses have been studied by researchers, there is still a dearth of information on image quality and patient dose with different techniques. Material and Methods: The...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of biomedical physics and engineering

جلد ۴، شماره ۴ DEC، صفحات ۰-۰

کلمات کلیدی
[ ' e n t r a n c e s k i n d o s e ' , ' t l d ' , 1 0 0 , ' r a n d o p h a n t o m ' ]

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023