a novel neutron dosimeter

نویسندگان

p. akhlaghi department of physics, faculty of sciences, ferdowsi university of mashhad, mashhad, iran

a. ebrahimi-khankook department of physics, faculty of sciences, ferdowsi university of mashhad, mashhad, iran

l. rafat-motavalli department of physics, faculty of sciences, ferdowsi university of mashhad, mashhad, iran

h. miri-hakimabad department of physics, faculty of sciences, ferdowsi university of mashhad, mashhad, iran

چکیده

background: neutron contamination in our environment can cause harmful biological effects on human body. therefore, many efforts have been made to construct a neutron dosimeter to estimate the received dose. objective: to design a simple neutron dosimeter. methods: the primary dosimeter had 3he as a spherical thermal neutron detector encircled by paraffin 10 cm in radius. then, the paraffin sphere was replaced with icru that contains soft tissue and dose equivalent determined as a desired output. finally, an appropriate relation between counts and dose equivalent was found. results: results on the energies below 1 mev demonstrated the similarity of changing process of these two quantities, so they could relate to each other with an adequate factor. to find the best fit, different factors considered and the smallest χ2 (goodness of fit) was 1.17×105 at the next step, two covers of cadmium and gadolinium, separately, put around the detector to improve χ2, which was 2.51×104 for cadmium cover and 6.33×103 for gadolinium cover. as we see, gadolinium cover fits the curves of counts and equivalent dose in a better way. conclusion: applying this simple dosimeter lead us to estimate whole body dose equivalent.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Neutron Dosimeter

Background: Neutron contamination in our environment can cause harmful biological effects on human body. Therefore, many efforts have been made to construct a neutron dosimeter to estimate the received dose. Objective: To design a simple neutron dosimeter. Methods: The primary dosimeter had 3He as a spherical thermal neutron detector encircled by paraffin 10 cm in radius. Then, the paraffin sph...

متن کامل

A search for novel thermoluminescent radiation dosimeter media.

We describe two example pilot efforts to help define new thermoluminescent dosimeter media. The first concerns ZnS:Mn nanophosphors, prepared by chemical precipitation using zinc and sodium sulfate, doped with manganese sulfate at concentrations varying from 1 to 3mol. The second concerns chemical vapor deposited diamond, produced as a thin film or as amorphous carbon on a single-crystal silico...

متن کامل

Preliminary investigation and application of a novel deformable PRESAGE® dosimeter

Deformable 3D dosimeters have potential applications in validating deformable dose mapping algorithms. This study evaluates a novel deformable PRESAGE® dosimeter and its application toward validating the deformable algorithm employed by VelocityAI. The deformable PRESAGE® dosimeter exhibited a linear dose response with a sensitivity of 0.0032 ΔOD/(Gy/cm). Comparison of an experimental dosimeter...

متن کامل

A novel approach to neutron dosimetry.

PURPOSE Having been overlooked for many years, research is now starting to take into account the directional distribution of neutron workplace fields. Existing neutron dosimetry instrumentation does not account for this directional distribution, resulting in conservative estimates of dose in neutron workplace fields (by around a factor of 2, although this is heavily dependent on the type of fie...

متن کامل

Is a quasi-3D dosimeter better than a 2D dosimeter for Tomotherapy delivery quality assurance?

Delivery quality assurance (DQA) has been performed for each Tomotherapy patient either using ArcCHECK or MatriXX Evolution in our clinic since 2012. ArcCHECK is a quasi-3D dosimeter whereas MatriXX is a 2D detector. A review of DQA results was performed for all patients in the last three years, a total of 221 DQA plans. These DQA plans came from 215 patients with a variety of treatment sites i...

متن کامل

A Novel Thin NIPAM Gel Cassette Dosimeter for Photon-Beam Radiotherapy

The response of thin polymer gel cassettes (called NIPAM gels) to ionizing radiation was investigated in this study. The NIPAM gels were prepared from gelatin, N-isopropyl acrylamide, tetrakis (hydroxymethyl) phosphoniumchloride, and N,N'-methylene-bis-acrylamide. Gel cassettes were irradiated in a phantom using a linear accelerator, and the polymerization morphology of irradiated NIPAM gel was...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of biomedical physics and engineering

جلد ۲، شماره ۲ Jun، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023