Experimental Study of a CO2 Thermal Battery for Simultaneous Cooling and Heating Applications

نویسندگان

  • Tianwei Wang
  • Supriya Dharkar
  • Orkan Kurtulus
  • Eckhard Groll
  • Kazuaki Yazawa
چکیده

This paper presents experimental investigations of the dynamics of a transcritical CO2 heat pump system with two thermal storages for simultaneous cooling and heating application. The preliminary results of the thermal battery are provided using a small-scale test bed that shows the accelerated penetration of renewable energy sources for building heating and cooling applications. The experimental system consists of a CO2 heat pump system with a compressor of 3 kW (1.02x104 BTU/hr) cooling capacity and two water tanks. During operation, the compressor and expansion valve are considered quasi-static. Thermal sensors are located in each of the two tanks to monitor the temperature gradient of water along the vertical orientation of the tank which impacts the overall system performance. Experiments are carried out under different water circulation flow rates for both the gas cooler and the evaporator in the heat pump, as well as under various discharge pressure conditions controlled by different charging rates and expansion valve openings. The impacts of water circulation flow rate and valve opening are reported in an effort to find the optimum coefficient-of-performance (COP). The results show that increasing the water inlet temperature in the gas cooler raises the discharge pressure significantly and drops the COP, whereas increasing the water temperature of the evaporator raises the discharge pressure relatively moderately. Although a larger water flow rate enhances the heat exchanger capacity and system COP, a smaller water flow rate seems to be preferable to maintain the thermal profile of the water tanks and to provide a more stable COP. At higher gas cooler water inlet temperature, the COP tends to increase with closing expansion valve. In this particular setup, the best COP is found to be approximately 7.0 at a specific expansion valve opening and at a discharge pressure between 75 and 83 bars (1088 to 1204 psia). The heating COP negatively corresponds to the water temperature at the gas cooler inlet. Experiments suggest the need of a proper control strategy and a matched tank capacity design. Based on these results, a 20% power enhancement may be possible by controlling the hot and cold water flow rates.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental and Numerical Investigations on Al2O3–Tricosane Based Heat Pipe Thermal Energy Storage

The enhancement of operating life cycle of electronic devices necessitates the development of efficient cooling techniques. Therefore, in the present work the effects of employment of Phase Change Material, in the adiabatic section of heat pipe for electronic cooling applications were experimentally and numerically investigated. Tricosane (100 ml) is chosen as PCM in this study, where Al2O3 nan...

متن کامل

Transient Two-Dimensional (r-z) Cyclic Charging/Discharging Analysis of Space Thermal Energy Storage Systems (RESEARCH NOTE)

A two-dimensional transient axi-symmetric model was developed to study the effects of various thermal and geometric parameters on cyclic heating and cooling modes of a phase-change thermal energy storage system. The high-temperature thermal energy storage device utilizes LiH for heat sink applications to store the waste heat generated during power-burst periods. The stored heat is then discharg...

متن کامل

Energy Optimization for Transcritical CO2 Heat Pumps for Combined Heating and Cooling and Thermal Storage Applications

A transcritical heat pump (THP) cycle using carbon dioxide (CO2) as the refrigerant is known to feature an excellent coefficient of performance (COP) as a thermodynamic system. Using this feature, we are designing and building a system that combines a water-to-water CO2 heat pump with both hot and cold thermal storages know as Thermal Battery (TB) (Blarke, 2012). Smart and effective use of inte...

متن کامل

Theoretical Study of Indirect Heating Temperature Swing Adsorption ‎in an Adsorbent Coated Finned Tube Heat Exchanger

In this study, the performance of an adsorbent coated finned tube exchanger for carbon capture was investigated numerically. The results showed that this structure has a great potential for being applied as a medium for CO2 capture by rapid indirect thermal swing adsorption. By using this structure, the recovery of 96%, and purity of 98% were achieved with a simple cycle consisting of two steps...

متن کامل

Improved nanofluid cooling of cylindrical lithium ion battery pack in charge/discharge operation using wavy/stair channels and copper sheath

Abstract: In order to improve the thermal management system for cooling an electric vehicle battery pack, the thermal performance of the battery pack in two states of charge and discharge in different working conditions by using a copper sheath around the batteries and a copper sheath, as well as a stair channel on top of the battery pack and using of nanofluid as cooling fluid, has been studie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014