Value of robotically assisted surgery for mitral valve disease.
نویسندگان
چکیده
IMPORTANCE The value of robotically assisted surgery for mitral valve disease is questioned because the high cost of care associated with robotic technology may outweigh its clinical benefits. OBJECTIVE To investigate conditions under which benefits of robotically assisted surgery mitigate high technology costs. DESIGN, SETTING, AND PARTICIPANTS Clinical cohort study at a large multispecialty academic medical center comparing costs of robotically assisted surgery with 3 contemporaneous conventional surgical approaches for degenerative mitral valve disease. From January 1, 2006, through December 31, 2010, a total of 1290 patients with a mean (SD) age of 57 (11) years underwent mitral valve repair for regurgitation from posterior leaflet prolapse. Robotically assisted surgery was performed in 473 patients, complete sternotomy in 227, partial sternotomy in 349, and anterolateral thoracotomy in 241. Comparisons were based on intent to treat, with 3 propensity-matched groups formed based on demographics, symptoms, cardiac and noncardiac comorbidities, valve pathophysiologic disorders, and echocardiographic measurements: robotic vs sternotomy (198 pairs) vs partial sternotomy (293 pairs) vs thoracotomy (224 pairs). INTERVENTIONS Mitral valve repair. MAIN OUTCOMES AND MEASURES Cost of care (expressed as robotic capital investment, maintenance of equipment, and direct technical hospital costs) and benefit of care (based on differences in recovery time). RESULTS Cost of care (median [15th and 85th percentiles]) for robotically assisted surgery exceeded that of alternative approaches by 26.8% (-5.3% and 67.9%), 32.1% (-6.1% and 69.6%), and 20.7% (-2.4% and 48.4%) for complete sternotomy, partial sternotomy, and anterolateral thoracotomy, respectively. Higher operative costs were partially offset by lower postoperative costs and earlier return to work: a median (15th and 85th percentiles) of 35 (19 and 63) days for robotically assisted surgery, 49 (21 and 109) days for complete sternotomy, 56 (30 and 119) days for partial sternotomy, and 42 (18 and 90) days for anterolateral thoracotomy. Resulting net differences (median [15th and 85th percentiles]) in the cost of robotic surgery vs the 3 alternatives were 15.6% (-14.7% and 55.1%), 15.7% (-19.4% and 51.2%), and 14.8% (-7.4% and 43.6%), respectively. Beyond a volume threshold of 55 to 100 robotically assisted operations per year, distribution of the cost of this technology broadly overlapped those of conventional approaches. CONCLUSIONS AND RELEVANCE In exchange for higher procedural costs, robotically assisted surgery for mitral valve repair offers the clinical benefit of least-invasive surgery, lowest postoperative cost, and fastest return to work. The value of robotically assisted surgery that is similar to that of conventional approaches can be realized only in high-volume centers.
منابع مشابه
Robotic mitral valve surgery: current limitations and future directions.
Use of the surgical robot facilitates less invasive mitral valve surgery. Although multiple single center studies confirmed excellent results with robotically-assisted mitral valve surgery, both real and perceived limitations have slowed adoption of this technology. Some still question the safety and efficacy of robotically-assisted mitral valve surgery. However, present data suggests that robo...
متن کاملRight sided heart evaluation after successful mitral valve replacement.
Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...
متن کاملHigh-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient
Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...
متن کاملHealth-Related Quality of Life after Valve Replacement Surgery
Background: Heart valve disease gradually increases the pressure in the heart chambers and impairs heart pumping. It influences on quality of life due to low output, disability, fear, amnesia, anxiety, and depression. Although most of signs and symptoms in patients with heart valve diseases may significantly decrease after valve replacement surgery, there is limited information about the impact...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JAMA surgery
دوره 149 7 شماره
صفحات -
تاریخ انتشار 2014