Association of insulin resistance, hyperleptinemia, and impaired nitric oxide release with in-stent restenosis in patients undergoing coronary stenting.

نویسندگان

  • PierMarco Piatti
  • Carlo Di Mario
  • Lucilla D Monti
  • Gabriele Fragasso
  • Fabio Sgura
  • Andrea Caumo
  • Emanuela Setola
  • Pietro Lucotti
  • Elena Galluccio
  • Cristina Ronchi
  • Anna Origgi
  • Ivana Zavaroni
  • Alberto Margonato
  • Antonio Colombo
چکیده

BACKGROUND Previously undiagnosed diabetes, impaired glucose tolerance, and insulin resistance are common in patients with acute myocardial infarction and coronary heart disease (CHD) and might be involved in early restenosis after stent implantation. To evaluate whether markers of insulin resistance syndrome, including leptin, and endothelial dysfunction are related to increased rate of early restenosis, we studied nondiabetic patients with CHD after successful coronary stenting. METHODS AND RESULTS Both patients with CHD undergoing coronary stenting (120 patients) and control subjects (58 patients) were submitted to an oral glucose tolerance test (OGTT). Fasting leptin levels and fasting and postglucose load insulin sensitivity were assessed. Endothelial function was measured by nitrite and nitrate release (NOx) during OGTT. More than 50% of patients treated with stent implantation presented impaired glucose tolerance or type 2 diabetes, which was previously undiagnosed. These patients also had higher glucose, insulin, and leptin levels than control subjects. Among the stented patients, insulin and leptin levels were higher in patients with restenosis than in patients without restenosis. A significant increase in NOx levels was found during OGTT both in patients without restenosis and in control subjects. On the contrary, NOx profiles were blunted in patients with restenosis. At multiple regression analysis, only DeltaAUC-NOx areas and insulin sensitivity index showed an independent correlation with the minimal lumen diameter at follow-up. CONCLUSIONS We demonstrated that insulin resistance and endothelial dysfunction are independent predictors of early restenosis after coronary stenting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hyperinsulinemia, hyperleptinemia, and nitric oxide in the regulation of membrane micoviscosity .

and Nitric Oxide in the Regulation of Membrane Micoviscosity To the Editor: We read with interest the article by Dr Piatti and colleagues1 dealing with the relationship between hyperinsulinemia, hyperleptinemia, and nitric oxide (NO) in patients with restenosis after coronary stenting. The results of their study demonstrated that among the stented patients, insulin and leptin levels were higher...

متن کامل

Association of G22A variant of Adenosine Deaminase gene with coronary in-stent restenosis in coronary artery patients receiving drug-eluting stent

In-stent restenosis (ISR) is regarded as the main problem in the utilization of stents in the treatment of coronary artery atherosclerotic stenosis in percutaneous coronary intervention (PCI). This study investigated the possible role of the G22A variant of the Adenosine Deaminase gene (ADA) in the development of ISR. In this study, 91 patients who underwent PCI were divided into two groups of ...

متن کامل

A randomized comparison of pioglitazone to inhibit restenosis after coronary stenting in patients with type 2 diabetes.

OBJECTIVE Recent studies have demonstrated that the treatment with thiazolidinediones reduces in-stent restenosis. The aim of this study was to elucidate the mechanism of the efficacy of pioglitazone for preventing in-stent restenosis in type 2 diabetic patients. RESEARCH DESIGN AND METHODS We conducted a prospective, randomized trial involving 54 type 2 diabetic patients referred for coronar...

متن کامل

Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent

Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...

متن کامل

Safety, Efficacy and Clinical Outcome of Direct Stent Implantation

Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 108 17  شماره 

صفحات  -

تاریخ انتشار 2003