Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system
نویسندگان
چکیده
A 56-year-old man underwent a single lead Lumax 640 DX implantable cardioverter defibrillator implantation for primary prevention of sudden cardiac death. A DX system consists of a single lead, which provides atrial as well as ventricular electrograms, and enhances atrial arrhythmia detection. Three months after the implantation, high-frequency episodes were detected on the far field and the atrial channels, but not on the bipolar right ventricular channel; these were classified as atrial tachycardia. In the present report, we discussed the unusual pattern of the artifacts that was related to an electromagnetic interference detected by the novel DX system.
منابع مشابه
THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملAbrupt increase in impedance measurements as detected via remote monitoring: What is the cause?
A 57-year-old man with nonischemic dilated cardiomyopathy, New York Heart Association class III heart failure, and a narrow QRS complex was enrolled in an ongoing research study to assess the impact of cardiac resynchronization therapy (CRT) in patients with echocardiographically detected dyssynchrony and a narrow QRS complex (the EchoCRT study; http://clinicaltrials.gov/show/NCT00683696.). A B...
متن کاملزندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیدهشناسی
Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملHome monitoring of implantable cardioverter-defibrillators: interpretation reliability of the second-generation “IEGM Online” system
AIMS Intracardiac electrograms (IEGMs) are essential for the assessment of implantable cardioverter-defibrillator (ICD) function. The Biotronik Home Monitoring systems transmit an 'IEGM Online' that is shorter than the full-length programmer IEGM due to technical constrains. The aim of this study was to evaluate the accuracy of the physician's classification of the underlying rhythm based on th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 32 شماره
صفحات -
تاریخ انتشار 2016