Measurement of carotid plaque volume by 3-dimensional ultrasound.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Measurement of carotid plaque volume and its progression are important tools for research and patient management. In this study, we investigate the observer variability in the measurement of plaque volume as determined by 3-dimensional (3D) ultrasound (US). We also investigate the effect of interslice distances (ISD) and repeated 3D US scans on measurement variability. Materials and Methods Forty 3D US patient images of plaques (range, 37.43 to 604.1 mm3) were measured by manual planimetry. We applied ANOVA to determine plaque volume measurement variability and reliability. Plaque volumes were measured with 9 ISDs to determine the effect of ISD on measurement variability. Additional plaque volumes were also measured from multiple 3D US scans to investigate repeated scan acquisition variability. Results Intraobserver and interobserver measurement reliabilities were 94% and 93.2%, respectively. Plaque volume measurement variability decreased with increasing plaque volume (range, 27.1% to 2.2%). Measurement precision was constant for ISDs between 1.0 and 3.0 mm, whereas plaque volume measurement variability increased with ISD. Repeated 3D US scan measurements were not different from single-scan measurements (P=0.867). Conclusions The coefficient of variation in the measurement of plaque volume decreased with plaque size. The volumetric change that must be observed to establish with 95% confidence that a plaque has undergone change is approximately 20% to 35% for plaques <100 mm3 and approximately 10% to 20% for plaques >100 mm3. Measurement precision was unchanged for ISDs <3.0 mm, whereas measurement variability increased with ISD. Repeated 3D US scans did not affect plaque volume measurement variability.
منابع مشابه
Ultrafast three-dimensional ultrasound: application to carotid artery imaging.
BACKGROUND AND PURPOSE Three-dimensional (3-D) vascular ultrasound can be expected to improve qualitative evaluation of vessel pathology and to provide quantitative data on vascular morphology and function. The objective of this study was to develop an ultrafast 3-D vascular system and to validate its performance for quantitation of atherosclerosis and assessment of regional arterial distensibi...
متن کاملCarotid ultrasound phenotypes in vulnerable populations
BACKGROUND Biomarkers of carotid atherosclerosis range from those that are widely available and relatively simple to measure such as serum cholesterol levels, and B-mode Ultrasound measurement of intima media thickness (IMT) to those that are more complex and technologically demanding but perhaps potentially more sensitive and specific to disease such as total plaque volume and total plaque are...
متن کاملSingle sweep three-dimensional carotid ultrasound: reproducibility in plaque and artery volume measurements.
BACKGROUND There is a need for non-invasive and accurate techniques for assessment of severity of atherosclerotic disease in the carotid arteries. Recently an automated single sweep three-dimensional ultrasound (3D US) technique became available. The aims of this study were to evaluate the feasibility and reproducibility of the automated single sweep method in a cohort of patients undergoing cl...
متن کاملThree-dimensional carotid ultrasound plaque texture predicts vascular events.
BACKGROUND AND PURPOSE Carotid ultrasound atherosclerosis measurements, including those of the arterial wall and plaque, provide a way to monitor patients at risk of vascular events. Our objective was to examine carotid ultrasound plaque texture measurements and the change in carotid plaque texture during 1 year in patients at risk of events and to compare these with measurements of plaque volu...
متن کاملThree-Dimensional Ultrasound of Carotid Plaque.
Measurement of plaque burden is different from measurement of carotid intima-media thickness (IMT). Carotid total plaque area is a stronger predictor of cardiovascular risk than IMT, and in contrast to progression of IMT, which does not predict cardiovascular events, progression of total plaque area and total plaque volume strongly predict cardiovascular events. Measurement of plaque burden is ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stroke
دوره 35 4 شماره
صفحات -
تاریخ انتشار 2004