Low intensity pulsed ultrasound for fracture healing: a review of the clinical evidence and the associated biological mechanism of action.
نویسندگان
چکیده
Low intensity pulsed ultrasound is used in the clinical treatment of fractures and other osseous defects. Level I clinical studies demonstrate the ability of a specific ultrasound signal (1.5 MHz ultrasound pulsed at 1 kHz, 20% duty cycle, 30 mW/cm(2) intensity (SATA)) to accelerate the healing time in fresh tibia, radius and scaphoid fractures by up to 40%. Additionally, the same ultrasound signal has been shown to be effective at resolving all types of nonunions of all ages, following a wide range of fracture types and primary fracture management techniques. Recently, significant efforts have resulted in a more comprehensive understanding of the biological mechanism of action that produces the documented clinical outcomes. Low intensity pulsed ultrasound has been demonstrated to accelerate in vivo all stages of the fracture repair process (inflammation, soft callus formation, hard callus formation). In particular, accelerated mineralisation has been demonstrated in vitro with increases in osteocalcin, alkaline phosphatase, VEGF and MMP-13 expression. Integrins, a family of mechanoreceptors present on a wide range of cells involved in the fracture healing process, have been shown to be activated by the ultrasound signal. Downstream of the integrin activation, focal adhesions occur on the surface of cells with the activation of multiple signalling pathways, including the ERK, NF-kappabeta, and PI3 kinase pathways. These pathways have been directly linked to the production of COX-2 and prostaglandin, which are key to the processes of mineralisation and endochondral ossification in fracture healing.
منابع مشابه
THE BEST DURATION OF LOW INTENSITY PULSED ULTRASOUND FOR ACCELERATING FRACTURED-RADIAL BONE REPAIR
We have already shown that low intensity pulsed ultrasonic treatment increases rabbit radial fracture healing. The present experiment was undertaken to find out the best duration for treatment. A complete transverse fracture was made in the right radial bones of21 adult male rabbits by a Stanley knife. The animals were divided into 4 groups: group 1, control groups 2, 3, and 4, experimental...
متن کاملLOW INTENSITY PULSED ULTRASOUND TREATMENT INCREASES RABBIT RADIAL FRACTURE HEALING
In order to study the effect of ultrasound (US) on bone healing, a complete transverse fracture was made in the right radius of adult male rabbits by a cutter. 52 rabbits were used: group I. control (n= 17): group 2. test (n:=: 15): group 3, intact (n= I) and group 4 (n= 12) who were examined only for evaluation of the cutter effects in detail. 7 animals were operated with a Gigli saw. The ...
متن کاملReview Paper: A Review on Brain Stimulation Using Low Intensity Focused Ultrasound
Brain stimulation techniques are important in both basic and clinical studies. Majority of well-known brain stimulating techniques have low spatial resolution or entail invasive processes. Low intensity focused ultrasound (LIFU) seems to be a proper candidate for dealing with such deficiencies. This review recapitulates studies which explored the effects of LIFU on brain str...
متن کاملLow-intensity pulsed ultrasound for bone healing: an overview.
Low-intensity ultrasound is a biophysical form of intervention in the fracture-repair process, which through several mechanisms accelerates healing of fresh fractures and enhances callus formation in delayed unions and nonunions. The goal of this review is to present the current knowledge obtained from basic science and animal studies, as well as existing evidence from clinical trials and case ...
متن کاملClinical applications of low-intensity pulsed ultrasound and its potential role in urology
Low-intensity pulsed ultrasound (LIPUS) is a form of ultrasound that delivered at a much lower intensity (<3 W/cm(2)) than traditional ultrasound energy and output in the mode of pulse wave, and it is typically used for therapeutic purpose in rehabilitation medicine. LIPUS has minimal thermal effects due to its low intensity and pulsed output mode, and its non-thermal effects which is normally ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Ultrasonics