Title Superconducting receiver coils for sodium magnetic resonance imaging

نویسندگان

  • J. R. Miller
  • K. Zhang
  • I. K. Mun
  • K. J. Jung
  • D. J. Kountz
چکیده

We present the results from sodium magnetic resonance imaging (MRI) experiments using high-temperature superconducting (HTS) receiver coils. Sodium imaging has been shown to have great potential for the assessment of cell integrity but suffers from a substantially lower signal-to-noise ratio (SNR) than that of hydrogen imaging. The use of an HTS receiver coil was found to significantly increase the SNR relative to an equivalent copper receiver coil at room temperature. The SNR gains afforded by HTS coils can also be used to decrease the imaging time.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

High Temperature Superconducting Radio Frequency Coils for Nmr Spectroscopy and Magnetic Resonance Imaging

High-temperature superconductivity has a significant opportunity to improve the performance of nuclear magnetic resonance (NMR) spectroscopy and magnetic resonance imaging (MRI) systems. The low rf losses and compact size of superconducting coils allow them to improve the signal-to-noise ratio in applications where the system noise dominates that of the sample under study. These improvements tr...

متن کامل

Radiofrequency coils for musculoskeletal magnetic resonance imaging.

Dedicated and specialized radiofrequency coils are critical for high quality musculoskeletal magnetic resonance imaging (MRI). Dedicated coils improve the signal to noise ratio, allowing for faster or higher resolution examinations. Transmit-receive coils can reduce heating at high field strength. Finally, novel radiofrequency coils can be used for assessment of tissue biochemistry, as seen wit...

متن کامل

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

Phase and sensitivity of receiver coils in magnetic resonance imaging.

Receiver coil response is a major cause of nonuniformities in magnetic resonance images. The spatial dependence of the sensitivity and phase of single-saddle receiver coils has been investigated quantitatively by calculating the H1 field and comparing the results with measurements of a uniform phantom. Agreement between the measurements and calculations is excellent. A method is developed which...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004