A new method for detecting anaerobic threshold by gas exchange.

نویسندگان

  • W L Beaver
  • K Wasserman
  • B J Whipp
چکیده

Excess CO2 is generated when lactate is increased during exercise because its [H+] is buffered primarily by HCO-3 (22 ml for each meq of lactic acid). We developed a method to detect the anaerobic threshold (AT), using computerized regression analysis of the slopes of the CO2 uptake (VCO2) vs. O2 uptake (VO2) plot, which detects the beginning of the excess CO2 output generated from the buffering of [H+], termed the V-slope method. From incremental exercise tests on 10 subjects, the point of excess CO2 output (AT) predicted closely the lactate and HCO-3 thresholds. The mean gas exchange AT was found to correspond to a small increment of lactate above the mathematically defined lactate threshold [0.50 +/- 0.34 (SD) meq/l] and not to differ significantly from the estimated HCO-3 threshold. The mean VO2 at AT computed by the V-slope analysis did not differ significantly from the mean value determined by a panel of six experienced reviewers using traditional visual methods, but the AT could be more reliably determined by the V-slope method. The respiratory compensation point, detected separately by examining the minute ventilation vs. VCO2 plot, was consistently higher than the AT (2.51 +/- 0.42 vs. 1.83 +/- 0.30 l/min of VO2). This method for determining the AT has significant advantages over others that depend on regular breathing pattern and respiratory chemosensitivity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory gas exchange in the assessment of patients with impaired ventricular function.

Respiratory gas exchange on exercise was evaluated as a non-invasive method of assessing patients with heart failure. Twenty four men (age 28-72) with symptomatic chronic stable heart failure (New York Heart Association class II-III) and ten controls aged 36-70 were studied. During treadmill exercise oxygen consumption and carbon dioxide production were measured continuously by analysis of mixe...

متن کامل

Respiratory gas exchange indices for estimating the anaerobic threshold.

Several methods are used for estimating the anaerobic threshold (AT) during exercise. The aim of the present study was to compare AT values based on blood lactate measurements with those obtained from computerised calculations of different respiratory gas indices. Twelve healthy, well-trained men performed a stepwise incremental test on both treadmill and cycle ergometer. Respiratory gases were...

متن کامل

Detecting abnormalities in left ventricular function during exercise by respiratory measurement.

The degree of exercise-induced cardiac dysfunction and its relation to the anaerobic threshold were evaluated in 23 patients with chronic heart disease. A symptom-limited exercise test was performed with a cycle ergometer with work rate increased by 1 W every 6 seconds. Left ventricular function, as reflected by ejection fraction, was continuously monitored with a computerized cadmium telluride...

متن کامل

The Impact of Exchange Rate Pass-Through via Domestic Prices on Inflation in Iran: New Evidence from a Threshold Regression

There are various causes for inflation in macroeconomics. One of the important channels of experiencing inflation is through the international economy caused by external shocks. In this context, the impact of exchange rate volatilities on domestic prices known as Exchange Rate Pass-Through (ERPT) plays a vital role. The present paper deals with the impact of Exchange Rate Pass-Through on inflat...

متن کامل

A method for detecting bubbles in two-phase gas-liquid flow

Detecting bubble in two-phase flow has been a basic issue in two-phase flow systems. A new method for measuring the frequency of bubble formation is presented in this paper. For this purpose, an electronic device was designed and constructed which works based on a change in intensity of laser beam. For this purpose, continues light beam is embedded just above the needle, which is received by a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 60 6  شماره 

صفحات  -

تاریخ انتشار 1986