Whole Prostate Volume and Shape Changes with the Use of an Inflatable and Flexible Endorectal Coil

نویسندگان

  • Murat Osman
  • Haytham Shebel
  • Sandeep Sankineni
  • Marcelino L Bernardo
  • Dagane Daar
  • Bradford J Wood
  • Peter A Pinto
  • Peter L Choyke
  • Baris Turkbey
  • Harsh K Agarwal
چکیده

Purpose. To determine to what extent an inflatable endorectal coil (ERC) affects whole prostate (WP) volume and shape during prostate MRI. Materials and Methods. 79 consecutive patients underwent T2W MRI at 3T first with a 6-channel surface coil and then with the combination of a 16-channel surface coil and ERC in the same imaging session. WP volume was assessed by manually contouring the prostate in each T2W axial slice. PSA density was also calculated. The maximum anterior-posterior (AP), left-right (LR), and craniocaudal (CC) prostate dimensions were measured. Changes in WP prostate volume, PSA density, and prostate dimensions were then evaluated. Results. In 79 patients, use of an ERC yielded no significant change in whole prostate volume (0.6 ± 5.7%, P = 0.270) and PSA density (-0.2 ± 5.6%, P = 0.768). However, use of an ERC significantly decreased the AP dimension of the prostate by -8.6 ± 7.8% (P < 0.001), increased LR dimension by 4.5 ± 5.8% (P < 0.001), and increased the CC dimension by 8.8 ± 6.9% (P < 0.001). Conclusion. Use of an ERC in prostate MRI results in the shape deformation of the prostate gland with no significant change in the volume of the prostate measured on T2W MRI. Therefore, WP volumes calculated on ERC MRI can be reliably used in clinical workflow.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Feasibility of Multi-Slice Endorectal Magnetic Resonance Elastography for Prostate Cancer Localization

Introduction: The stiffness of malignant prostate tissue is elevated as compared to normal or benign tissue, which suggests that the biomechanical properties of prostate tissue may be an independent marker for prostate cancer. Using dynamic MR elastography, micrometer amplitude shear waves are propagated into tissue, and the resulting tissue displacements are measured to calculate the underlyin...

متن کامل

Advantages of inflatable multichannel endorectal applicator in the neo‐adjuvant treatment of patients with locally advanced rectal cancer with HDR brachytherapy

High-dose rate endorectal brachytherapy (HDR-EBT) is mainly used as a palliative treatment modality. In this paper, we compare dosimetry distributions for a single-channel catheter (Miami) applicator with distributions of the inflatable multichannel (Novi Sad) endorectal applicator. The comparisons were made with respect to dose coverage to the clinical tumor volume as well as to the bladder, r...

متن کامل

Impact of the use of an endorectal coil for 3 T prostate MRI on image quality and cancer detection rate

This work aims to assess the impact of an additional endorectal coil on image quality and cancer detection rate within the same patients. At a single academic medical center, this transversal study included 41 men who underwent T2- and diffusion-weighted imaging at 3 T using surface coils only or in combination with an endorectal coil in the same session. Two blinded readers (A and B) randomly ...

متن کامل

Phased-array MRI of canine prostate using endorectal and endourethral coils.

A four-channel phased array consisting of one surface coil, two endorectal coils, and one flexible endourethral loop coil was designed for MRI of the canine prostate. The endorectal coils provide high signal in the posterior region of the prostate, while the endourethral and surface coils are sensitive to the central and anterior regions of the prostate. Gel phantom experiments indicate that th...

متن کامل

MR Spectroscopic Imaging of Peripheral Zone in Prostate Cancer Using a 3T MRI Scanner: Endorectal versus External Phased Array Coils

Magnetic resonance spectroscopic imaging (MRSI) detects alterations in major prostate metabolites, such as citrate (Cit), creatine (Cr), and choline (Ch). We evaluated the sensitivity and accuracy of three-dimensional MRSI of prostate using an endorectal compared to an external phased array "receive" coil on a 3T MRI scanner. Eighteen patients with prostate cancer (PCa) who underwent endorectal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014