Cardiac magnetic resonance T2 mapping in the monitoring and follow-up of acute cardiac transplant rejection: a pilot study.

نویسندگان

  • Asad A Usman
  • Kirsi Taimen
  • Marie Wasielewski
  • Jennifer McDonald
  • Saurabh Shah
  • Shivraman Giri
  • William Cotts
  • Edwin McGee
  • Robert Gordon
  • Jeremy D Collins
  • Michael Markl
  • James C Carr
چکیده

BACKGROUND Acute rejection is a major factor impacting survival in the first 12 months after cardiac transplantation. Transplant monitoring requires invasive techniques. Cardiac magnetic resonance (CMR), noninvasive testing, has been used in monitoring heart transplants. Prolonged T2 relaxation has been related to transplant edema and possibly rejection. We hypothesize that prolonged T2 reflects transplant rejection and that quantitative T2 mapping will concur with the pathological and clinical findings of acute rejection. METHODS AND RESULTS Patients were recruited within the first year after transplantation. Biopsies were graded according to the International Society for Heart Lung Transplant system for cellular rejection with immunohistochemistry for humoral rejection. Rejection was also considered if patients presented with signs and symptoms of hemodynamic compromise without biopsy evidence of rejection who subsequently improved with treatment. Patients underwent a novel single-shot T2-prepared steady-state free precession 4-chamber and 3 short axis sequences and regions of interest were drawn overlying T2 maps by 2 independent blinded reviewers. A total of 74 (68 analyzable) CMRs T2 maps in 53 patients were performed. There were 4 cellular, 2 humoral, and 2 hemodynamic rejection cases. The average T2 relaxation time for grade 0R (n=46) and grade 1R (n=17) was 52.5±2.2 and 53.1±3.3 ms (mean±SD), respectively. The average T2 relaxation for grade 2R (n=3) was 59.6±3.1 ms and 3R (n=1) was 60.3 ms (all P value <0.05 compared with controls). The T2 average in humoral rejection cases (n=2) was 59.2±3.3 ms and the hemodynamic rejection (n=2) was 61.1±1.8 ms (P<0.05 versus controls). The average T2 relaxation time for all-cause rejection versus no rejection is 60.1±2.1 versus 52.8±2.7 ms (P<0.05). All rejection cases were rescanned 2.5 months after treatment and demonstrated T2 normalization with average of 51.4±1.6 ms. No difference was found in ventricular function between nonrejection and rejection patients, except in ventricular mass 107.8±10.3 versus 127.5±10.4 g (P < 0.05). CONCLUSIONS Quantitative T2 mapping offers a novel noninvasive tool for transplant monitoring, and these initial findings suggest potential use in characterizing rejections. Given the limited numbers, a larger multi-institution study may help elucidate the benefits of T2 mapping as an adjunctive tool in routine monitoring of cardiac transplants.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac magnetic resonance T2 mapping for monitoring acute cardiac transplant rejection

Introduction Cardiac transplantation is the treatment for some patients with end-stage heart failure. After transplantation asymptomatic acute allograft rejection is a major factor impacting survival in the first 12 months. Current transplant monitoring requires frequent right heart catheterizations, endomyocardial biopsies (EMB), and echocardiography. CMR imaging, comparatively less invasive, ...

متن کامل

Cardiac Magnetic Resonance in heart transplant patients: diagnostic value of quantitative tissue markers (T2 mapping and ECV) for acute cardiac rejection diagnosis

Background The diagnosis of acute cardiac rejection (AR) still requires invasive technique with endomyocardial biopsy (EMB) which has important risks and limitations. Cardiac Magnetic Resonance (CMR) with recently T2 and T1 mapping is a promising technique for characterizing myocardial tissue. The purpose of the study was to evaluate T2, T1 and extracellular volume (ECV) quantification as novel...

متن کامل

Cardiac and Hepatic T2*-Weighted Magnetic Resonance Imaging

Abstract Background Iron overload is the main transfusion related side effects in patients with transfusion dependent hemoglobinopathies. Severe iron deposition in tissues leads to organ dysfunction. Many organs can be affected such as heart, liver, and endocrine organs. Cardiac failure and liver fibrosis are the consequent of Iron overload in transfusion dependent hemoglobinopathy. Magne...

متن کامل

Correlation between QRS Complex Changes and Cardiac Iron Overload in Beta Thalassemia Major Patients Using T2*MRI

Background and purpose: Cardiac magnetic resonance imaging (MRI) is a costly method to assess cardiac iron overload. The presence of fragmented QRS (fQRS) indicates changes due to iron overload in cardiac tissue. The aim of this study was to evaluate the correlation between fQRS and cardiac iron overload using cardiac MRI in patients with β-thalassemia major (β-TM). Materials and methods: This...

متن کامل

Magnetic resonance imaging of the transplanted pediatric heart as a potential predictor of rejection

AIM To evaluate cardiac magnetic resonance imaging (CMR) as a non-invasive tool to detect acute cellular rejection (ACR) in children after heart transplant (HT). METHODS Thirty pediatric HT recipients underwent CMR at the time of surveillance endomyocardial biopsy (EMB) and results were compared to 14 non-transplant controls. Biventricular volumes, ejection fractions (EFs), T2-weighted signal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 5 6  شماره 

صفحات  -

تاریخ انتشار 2012