Quantitative Neutron Dark-field Imaging through Spin-Echo Interferometry

نویسندگان

  • Markus Strobl
  • Morten Sales
  • Jeroen Plomp
  • Wim G. Bouwman
  • Anton S. Tremsin
  • Anders Kaestner
  • Catherine Pappas
  • Klaus Habicht
چکیده

Neutron dark-field imaging constitutes a seminal progress in the field of neutron imaging as it combines real space resolution capability with information provided by one of the most significant neutron scattering techniques, namely small angle scattering. The success of structural characterizations bridging the gap between macroscopic and microscopic features has been enabled by the introduction of grating interferometers so far. The induced interference pattern, a spatial beam modulation, allows for mapping of small-angle scattering signals and hence addressing microstructures beyond direct spatial resolution of the imaging system with high efficiency. However, to date the quantification in the small angle scattering regime is severely limited by the monochromatic approach. To overcome such drawback we here introduce an alternative and more flexible method of interferometric beam modulation utilizing a spin-echo technique. This novel method facilitates straightforward quantitative dark-field neutron imaging, i.e. the required quantitative microstructural characterization combined with real space image resolution. For the first time quantitative microstructural reciprocal space information from small angle neutron scattering becomes available together with macroscopic image information creating the potential to quantify several orders of magnitude in structure sizes simultaneously.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Observation on the Visibility Decrease in a VCN Spin Resonator Interferometry

The present paper reports on the detailed studies concerning the neutron spin interference visibility observed after transmitting through multilayer magnetic resonators in a spin echo condition with very cold neutrons from a high flux reactor. The observed visibility of the interference between upward and downward spin components perpendicular to the Larmor precession plane of the neutron spin ...

متن کامل

High resolution 3D spiral coronary vessel wall imaging with >99% respiratory efficiency using beat to beat respiratory motion correction: quantitative comparison with navigator gated 2D spiral and turbo spin echo imaging

Introduction: Dark blood coronary artery wall imaging has demonstrated the ability to detect vessel wall thickening in subjects with non-significant coronary heart disease [1]. For high resolution imaging, studies are generally performed with diaphragmatic navigator gating which has an inherently low respiratory efficiency (RE) and is further compromised by respiratory drift through the long ac...

متن کامل

Neutron wave-interference experiments with adiabatic passage of neutron spin through resonant coils

Neutron resonance spin echo phenomena, produced by resonance coils with adiabatic passage of the neutron spin, are investigated experimentally and theoretically. The adiabatic passage of the neutron spin through a resonance coil requires a specific configuration of the magnetic field. The solution of the Schrödinger equation, obtained for the required configuration, shows the probability of a s...

متن کامل

Schroedinger cat-like neutron states and Wigner function formulation of interferometry and spin-echo experiments

The formalism of quantum optics can be adapted to advanced neutron optics. Measurements and calculations have identified a characteristic coherent and squeezed state behaviour for neutron states and a transfer of coherence features between ordinary and momentum space. In certain cases, the neutron occupies two well-separated regions in ordinary space which are coupled in momentum space giving a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015