Coronary thermodilution to assess flow reserve: validation in humans.

نویسندگان

  • Nico H J Pijls
  • Bernard De Bruyne
  • Leif Smith
  • Wilbert Aarnoudse
  • Emanuele Barbato
  • Jozef Bartunek
  • G Jan Willem Bech
  • Frans Van De Vosse
چکیده

BACKGROUND Guide wire-based simultaneous measurement of fractional flow reserve (FFR) and coronary flow reserve (CFR) is important to understand microvascular disease of the heart. The aim of this study was to investigate the feasibility of simultaneous measurement of FFR and CFR by one pressure-temperature sensor-tipped guide wire with the use of coronary thermodilution and to compare CFR by thermodilution (CFR(thermo)) with simultaneously measured Doppler CFR (CFR(Doppl)). METHODS AND RESULTS In 103 coronary arteries in 50 patients, a pressure-temperature sensor-tipped 0.014-inch floppy guide wire and a 0.014-inch Doppler guide wire were introduced. Both normal vessels and a wide range of stenotic vessels were included. With 3 mL of saline at room temperature used as an indicator, by hand-injection, thermodilution curves in the coronary artery were obtained in triplicate, both at baseline and at intravenous adenosine-induced maximum hyperemia. After adequate curve-fitting, CFR(thermo) was calculated from the ratio of inverse mean transit times and compared with CFR(Doppl) calculated by velocities at hyperemia and baseline. Adequate sets of thermodilution curves and corresponding CFR(thermo) could be obtained in 87% of the arteries versus 91% for Doppler CFR and 100% for FFR. CFR(thermo) correlated fairly well to CFR(Doppl) (CFR(thermo)=0.84 CFR(Doppl)+0.17; r=0.80; P<0.001), although individual differences of >20% between both indexes were seen in a quarter of all arteries. CONCLUSIONS This study shows the feasibility of simultaneous measurement of FFR (by coronary pressure) and CFR (by coronary thermodilution) in humans by one single guide wire in a practical and straightforward way and will facilitate assessment of microvascular disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simple thermodilution technique to assess coronary endothelium-dependent microvascular function in humans: validation and comparison with coronary flow reserve.

AIMS To validate a novel method for assessment of coronary endothelium-dependent microvascular function and compare this index with the adenosine-derived coronary flow reserve (CFR). METHODS AND RESULTS We validated use of intra-coronary pressure wire-derived thermodilution to assess changes in coronary flow compared to Doppler flow-wire/quantitative coronary angiography- (QCA) derived data i...

متن کامل

Coronary thermodilution to assess flow reserve: experimental validation.

BACKGROUND Fractional flow reserve (FFR) and coronary flow reserve (CFR) are indices of coronary stenosis severity that provide the clinician with complementary information on the contribution of epicardial arteries and microcirculation to total resistance to myocardial blood flow. At present, FFR and CFR can only be obtained by 2 separate guidewires. The present study tested the validity of th...

متن کامل

In vivo validation of a thermodilution method to determine regional left ventricular blood flow in patients with coronary disease.

Several methods have been used to measure left ventricular regional blood flow in humans. However, limitations and lack of validation in patients are major problems. A continuous thermodilution technique to measure regional left ventricular blood flow in patients with coronary disease was validated in vivo. This technique permits simultaneous assessment of venous blood flow draining predominant...

متن کامل

Direct volumetric blood flow measurement in coronary arteries by thermodilution.

OBJECTIVES This study sought to validate a new method for direct volumetric blood flow measurement in coronary arteries in animals and in conscious humans during cardiac catheterization. BACKGROUND Direct volumetric measurement of blood flow in selective coronary arteries would be useful for studying the coronary circulation. METHODS Based on the principle of thermodilution with continuous ...

متن کامل

Pressure-derived measurement of coronary flow reserve.

OBJECTIVES We aimed to validate the technique of measuring the coronary flow reserve (CFR) with coronary pressure measurements against an established thermodilution technique. BACKGROUND The CFR has traditionally required measurement of coronary blood flow velocity with the Doppler wire and, more recently, using a thermodilution technique with the coronary pressure wire. However, recent work ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 105 21  شماره 

صفحات  -

تاریخ انتشار 2002