Absolute determination of cardiac output in intra-aortic balloon pumped patients using the radial arterial pressure trace.

نویسنده

  • G A Herzlinger
چکیده

We describe a new method for the absolute determination of cardiac output in intra-aortic balloon pumped (IABP) patients. The method uses the known pumping volume of the IABP balloon and the radial arterial pressure trace, which is commonly used to monitor IABP patients, to determine the cardiac output. Two pressure excursions denoted by P1-P0 and P2-P0, characterizing IABP balloon deflation, and ventricular ejection, respectively, are extracted from the radial trace. The cardiac output (CO) is then determined by the simple relation: CO = (BV) x (P2-P0)/(P1-P0) x HR where HR is the heart rate, and the value for pumped balloon volume (BV) is corrected for the effect of the pressure in the patient's aorta. Comparison with dye dilution and thermal dilution procedures as carried out on a routine basis in a clinical setting produced a good correlation (r = .928). When fit to a straight line through zero output, the data yielded a constant of proportionality of 0.973 between the above formula and the clinical procedures. The procedure does not disturb the patient in any way, and enables continuous monitoring of cardiac output. This has been implemented using a real-time, miniaturized computer and allows much more information to be obtained than in usual single measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery

Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In thi...

متن کامل

Comparison of the right internal thoracic artery and radial artery as a second arterial conduit in ‘Y’ composite fashion in patients undergoing coronary artery bypass grafting using total arterial revascularization

Introduction: The use of two arterial conduits for CABG is rapidly increasing. The second arterial conduit to LITA is usually RITA or radial artery. We sought to compare outcomes when either RITA or radial artery is exclusively used as a Y composite graft to LITA for total arterial revascularization. Material and methods:  We retrospectively analyzed 231 ...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Computational Quantification of the Cardiac Energy Consumption during Intra-Aortic Balloon Pumping Using a Cardiac Electromechanics Model

To quantify the reduction in workload during intra-aortic balloon pump (IABP) therapy, indirect parameters are used, such as the mean arterial pressure during diastole, product of heart rate and peak systolic pressure, and pressure-volume area. Therefore, we investigated the cardiac energy consumption during IABP therapy using a cardiac electromechanics model. We incorporated an IABP function i...

متن کامل

Computational analysis of aortic hemodynamics during total and partial extracorporeal membrane oxygenation and intra-aortic balloon pump support.

PURPOSE The extracorporeal membrane oxygenation (ECMO) is a temporary, but prolonged circulatory support for cardiopulmonary failure. Clinical evidence suggests that pulsed flow is healthier than non pulsatile perfusion. The aim of this study was to computationally evaluate the effects of total and partial ECMO assistance and pulsed flow on hemodynamics in a patient-specific aorta model. METH...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 53 3  شماره 

صفحات  -

تاریخ انتشار 1976