Initial experience of transcatheter closure of subarterial VSD with the Amplatzer duct occluder.

نویسندگان

  • Tsung-Cheng Shyu
  • Ming-Chih Lin
  • Yeak-Wun Quek
  • Sheng-Je Lin
  • Hean-Pat Saw
  • Sheng-Ling Jan
  • Yun-Ching Fu
چکیده

BACKGROUND The traditional treatment of subarterial ventricular septal defect (VSD) is open heart surgery. This study aimed to evaluate the feasibility, safety and outcome of transcatheter closure with the Amplatzer duct occluder (ADO). METHODS Between March 2012 and June 2015, a total of 16 patients (8 male and 8 female) with subarterial VSD who underwent transcatheter closure with the ADO were enrolled retrospectively. Their age ranged from 3.0 to 65.6 years, with the median of 35.6 years; their body weights ranged from 14 to 92 kg with the median of 60 kg. All patients had prolapse of the right coronary cusp without subaortic rim. Mild aortic regurgitation was noted in 11 (69%) patients. RESULTS Left ventriculogram showed VSD size ranged from 1.3 to 9.3 mm with the median of 3.5 mm. The device was successfully implanted in 88% (14/16) of the patients. Although one patient had mild skin allergy to contrast medium, no other complication was noted. Complete closure rate was 64%, 86%, 86% and 86% at 1-day, 1-month, 6-month and 12-month follow-up, respectively. Two patients developed new or worsening aortic regurgitation during follow-up. CONCLUSION Transcatheter closure of subarterial VSD with ADO is technically feasible and safe in patients older than 7 years of age. However, development or worsening of aortic regurgitation requires long-term follow-up.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous closure of perimembranous ventricular septal defects with Amplatzer occluders--a single centre experience.

BACKGROUND Perimembranous ventricular septal defect (VSD) is the most common congenital heart defect. Percutaneous transcatheter closure of VSD is one of the greatest challenges in interventional cardiology. AIM Presentation of our experience in transcatheter closure of perimembranous VSD. METHODS Eighteen patients were treated. Nine patients (group I) had VSD closed with implant Amplatzer ...

متن کامل

Transcatheter closure of ventricular septal defects using the Amplatzer Duct Occluder II device: a single-center experience

INTRODUCTION Off-label use of different devices has been described for percutaneous closure of ventricular septal defects (VSD) because of the unacceptable rate of post-procedure heart block associated with special VSD devices. AIM To describe the early single-center clinical experience with closure of a VSD using the Amplatzer Duct Occluder II (ADO II) device in children. MATERIAL AND METH...

متن کامل

Transcatheter closure of left coronary cameral fistula with Amplatzer duct occluder II.

The surgical and transcatheter coil closure of coronary arterial fistulas are described in the literature. We report our experience with the successful transcatheter closure of a coronary arterial fistula, arising from the left coronary artery and draining into the right ventricle, with the new Amplatzer duct occluder II device.

متن کامل

Transcatheter closure of ventricular septal defects with nitinol wire occluders of type patent ductus arteriosus

Ventricular septal defects closure (VSD) depending on the anatomy and clinical setting can be performed surgically or by a hybrid and transcatheter approach. Two cases of children with VSD will be presented. Patients' defects were closed with various types of occluders made of nitinol wire mesh occluder, patent ductus arteriosus (PDA) type. The first case was a 2.5-year-old boy after cardiosurg...

متن کامل

Transcatheter closure of patent arterial duct with amplatzer duct occluder II additional sizes in children.

Amplatzer duct occluder II additional sizes is a new generation of device for arterial duct closure, appropriate for infants and older children. We report the successful transcatheter closure of the arterial duct in an infant and two older children with the above-mentioned device.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the Chinese Medical Association : JCMA

دوره 80 8  شماره 

صفحات  -

تاریخ انتشار 2017