Evaluation of polymer-based comparator drug-eluting stents using a rabbit model of iliac artery atherosclerosis.
نویسندگان
چکیده
BACKGROUND Although atherosclerotic models, especially in the rabbit, have existed for a long time, a comparative study of various drug-eluting stent (DES) implantations in atherosclerotic arteries have not been systematically studied. METHODS AND RESULTS New Zealand White rabbits (n=44) with induced atheroma received bilateral iliac artery stents: bare metal stent (BMS) (Driver) or a stent eluting zotarolimus (ZES) (Endeavor), sirolimus (SES) (Cypher), or everolimus (EES) (Xience V). After 28 days, tissues were harvested for histomorphometric analyses, en face analysis of endothelial coverage, and expression of endothelial nitric oxide synthase (eNOS). Area measurements of external elastic lamina and stent area were similar. Neointimal area was significantly less in all DES versus BMS, which was least in SES and EES; similar trends were noted for cell proliferation. Uncovered struts were greater for SES and EES and least in BMS, whereas ZES were in between and associated with the least fibrin. Macrophages of the neointima were significantly less for all DES relative to BMS. Plaque calcification underneath stents, however, was significantly greater in SES and ZES than in BMS. Although endothelial coverage in between struts was comparable between BMS and DES, there was significantly greater expression of eNOS in BMS and ZES relative to EES and SES. CONCLUSIONS The rabbit atherosclerotic model of stenting showed delayed healing and significantly greater reduction of neointima following implantation of SES and EES; however, delayed healing was less in ZES with greater neointima (but less than BMS), endothelial regrowth, and eNOS expression.
منابع مشابه
Comparison of Vascular Responses Following New‐Generation Biodegradable and Durable Polymer‐Based Drug‐Eluting Stent Implantation in an Atherosclerotic Rabbit Iliac Artery Model
BACKGROUND Incomplete endothelialization is the primary substrate of late stent thrombosis; however, recent reports have revealed that abnormal vascular responses are also responsible for the occurrence of late stent failure. The aim of the current study was to assess vascular response following deployment of biodegradable polymer-based Synergy (Boston Scientific) and Nobori (Terumo) drug-eluti...
متن کاملAn advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries
Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...
متن کاملVASCULAR BIOLOGY Original Studies In Vivo Comparison of a Polymer-Free Biolimus A9-Eluting Stent With a Biodegradable Polymer-Based Biolimus A9 Eluting Stent and a Bare Metal Stent in Balloon Denuded and Radiated Hypercholesterolemic Rabbit Iliac Arteries
Objectives: To evaluate the effect of a polymer-free Biolimus A9-eluting stent [BioFreedom (BF)], compared with that of a biodegradable polymer-based Biolimus A9-eluting stent [BioMatrix Flex (BMF)] and a bare metal stent (BMS) in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries. Methods: Rabbits were fed with 1% cholesterol diet (n 5 14) for 14 days, both iliac arteries ...
متن کاملA Polymer Coated Cicaprost-Eluting StentIncreases Neointima Formation and Impairs Vessel Function in the Rabbit Iliac Artery
Drug-eluting stents have been successful in reducing in-stent restenosis but are not suitable for all lesion types and have been implicated in causing late stent thrombosis due to incomplete regeneration of the endothelial cell layer. In this study we implanted stents coated with cicaprost, a prostacyclin analogue with a long plasma half-life and antiproliferative effects on vascular smooth mus...
متن کاملAssessment of stent strut endothelialization in iliac arteries of rabbits.
BACKGROUND Fast post-implantation stent endothelialization is desirable for theoretically reducing the possibility of stent thrombosis. OBJECTIVE To evaluate the extent of sirolimus-eluting stent strut endothelialization (delivered from the luminal and abluminal aspects or abluminal aspect only) in the iliac arteries of rabbits. METHODS The iliac arteries of 10 rabbits were implanted with f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 4 1 شماره
صفحات -
تاریخ انتشار 2011