Background—Long-term biological effects of ionizing radiation on coronary arteries remain poorly defined. We examined late arterial responses 6 months after balloon angioplasty and -radiation in normal pig coronary arteries. Methods and Results—Coronary arteries of 25 adult pigs were randomized to receive 20 Gy (n 8) or 30 Gy (n 9) of Re -radiation or sham radiation (n 8) immediately after balloon angioplasty. Aspirin was given daily during follow-up. The study vessels were analyzed histopathologically at 6 months. -Radiation decreased lumen area (20 Gy, 1.55 0.99 mm; 30 Gy, 1.03 0.82 mm; and 0 Gy, 2.05 0.80 mm; P 0.05) but not overall vessel area. The neointimal area was significantly larger within the injured segment with -radiation (20 Gy, 1.92 1.23 mm; 30 Gy, 1.51 0.97 mm; and 0 Gy, 0.89 0.31 mm; 0 Gy versus 20 Gy, P 0.05), and a significant increase of edge stenosis was observed with -radiation. Irradiated vessels also had larger thrombus areas within the neointima (30 Gy, 0.24 0.61 mm; 20 Gy, 0.98 1.57 mm2; and 0 Gy, 0.00 0.01 mm; P 0.05) and larger adventitial areas (20 Gy, 2.25 0.75 mm; 30 Gy, 2.38 0.98 mm; and 0 Gy, 1.23 0.29 mm; 0 Gy versus 20 or 30 Gy, P 0.05) that showed substantial collagen accumulation. Conclusions—Intracoronary -radiation did not inhibit neointima formation in balloon-injured normal pig coronary arteries 6 months after the interventional procedure. Unresorbed thrombus contributed to, but was not the sole component of, augmented neointima formation. Irradiated vessels demonstrated more adventitial thickening and fibrosis. These observations may have relevance for long-term clinical outcomes after intracoronary -radiation. (Circulation. 2001;104:2459-2464.)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intracoronary beta-radiation exacerbates long-term neointima formation in balloon-injured pig coronary arteries.

BACKGROUND Long-term biological effects of ionizing radiation on coronary arteries remain poorly defined. We examined late arterial responses 6 months after balloon angioplasty and beta-radiation in normal pig coronary arteries. METHODS AND RESULTS Coronary arteries of 25 adult pigs were randomized to receive 20 Gy (n=8) or 30 Gy (n=9) of (186)Re beta-radiation or sham radiation (n=8) immedia...

متن کامل

Vascular repair after balloon overstretch injury in porcine model effects of intracoronary radiation.

OBJECTIVES The purpose of this study was to evaluate the effect of IR on thrombus formation and dissection repair following overstretch balloon injury in porcine coronary arteries. BACKGROUND Exposure of blood to the injured arterial wall after percutaneous transluminal coronary angioplasty (PTCA) induces thrombus formation and inflammation in the dissection plane. Neointima formation is rela...

متن کامل

Effects of intracoronary radiation on thrombosis after balloon overstretch injury in the porcine model.

BACKGROUND The main complications of PTCA remain thrombosis and restenosis. Recent studies have demonstrated reduction in the neointimal hyperplasia after intracoronary radiation (IR) with doses of 10 to 25 Gy of ionizing radiation delivered by either beta- or gamma-emitters to injured vessels. The purpose of this study was to examine the effect of ionizing radiation on the thrombosis rate (TR)...

متن کامل

Short-term local delivery of an inhibitor of Ras farnesyltransferase prevents neointima formation in vivo after porcine coronary balloon angioplasty.

BACKGROUND Mitogenic stimuli present at the site of coronary arterial balloon injury contribute to the progression and development of a restenotic lesion, many signaling through a common pathway involving the small G protein p21(ras). Our aim was to demonstrate in biochemical studies that farnesyl protein transferase inhibitor III (FPTIII) is an inhibitor of p21(ras) processing and that when it...

متن کامل

Long-term effects of intracoronary beta-radiation in balloon- and stent-injured porcine coronary arteries.

BACKGROUND The data on the long-term safety and efficacy of intracoronary beta-radiation in animal models are limited. METHODS AND RESULTS A total of 30 coronary arteries in 15 swine were subjected to balloon or stent injury followed by beta-radiation from a centered 32P source (2000 cGy to 1 mm beyond lumen surface) or a sham radiation procedure. The animals received aspirin for 6 months and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001