Re: "Initial experience with the 5×300-mm Proteus Embolic Capture Angioplasty balloon in the treatment of peripheral vascular disease".
نویسندگان
چکیده
PURPOSE To describe the use of the 5 × 300-mm Proteus embolic capture angioplasty (ECA) balloon catheter to reduce embolic burden in complex TASC II (TransAtlantic Inter-Society Consensus) C and D femoropopliteal interventions. METHODS A non-randomized safety and feasibility study was conducted at 2 centers enrolling 15 subjects (9 women; mean age 72.5 ± 9.5 years, range 53-85) suffering from Rutherford-Becker category 2 to 4 occlusive disease. Of the 20 lesions in 15 limbs, 16 were TASC II D and 4 were TASC II C. Average baseline stenosis was 95%± 12%; 16 lesions were totally occluded. Half of the lesions were de novo, 5 were restenotic, and 5 were in-stent stenoses. Average lesion length was 284 ± 50 mm. In addition to using the ECA device, 18 of the target lesions were treated with stents and 4 with rotational thrombectomy devices. Distal angiography was performed before and after use of the ECA device to locate any periprocedural embolic events. RESULTS Procedural success was achieved in 100% lesions. The ECA balloon was used for predilation in 11 lesions and for postdilation in 9. No distal embolization or flow-limiting vessel dissections were observed despite the complex nature of the cases. Three non-device-related complications were reported (pseudoaneurysm, myocardial infarction, acute renal failure) and resolved without sequelae within 30 days. Analysis of the particles recovered from 5 ECA balloons demonstrated a mean 257 ± 185 particles, with a mean major axial dimension of 0.54 ± 0.04 mm (range 0.11-7.54). There were a mean 7.67 ± 6.03 particles >2 mm in diameter, and all samples contained 1 to 3 particles >4 mm in diameter. CONCLUSION In this small series, the 5 × 300-mm ECA embolic capture balloon catheter was an effective tool for avoiding embolic events in long peripheral lesions, with a good safety profile. The device might be considered as part of routine clinical practice for complex TASC II C/D femoropopliteal lesions.
منابع مشابه
Immediate and Short-term Follow-Up of Aortic Coarctation Balloon Angioplasty and Stenting
Background Aortic Coarcatation (CoA) is one of the congenital heart diseases with the rate of 5-8% of Coronary heart diseases(CHDs). Balloon angioplasty is now one of the effective way of treatment for CoA, native or Re-coarctation (Re-CoA). We aimed to assess the immediate, and short term response to angioplasty and stenting, and also complications. Materials and Methods Balloon angioplasty wi...
متن کاملThe experience use of drug-coated & non drug-coated balloons in arteriovenous fistula at a six months period: brief report
Background: The ineffectiveness of hemodialysis fistulas causes high costs and increases mortality and morbidity rates. The efficacy of drug-coated balloon and nondrug-coated balloon in dysfunctional arteriovenous Fistula was evaluated over six month period. Methods: In this randomized clinical trial, a total of a total of 50 hemodialysis patients who referred to Imam Reza Hospital in Kermansh...
متن کاملUsing 6-mm Cutting Balloon angioplasty in patients with resistant peripheral artery stenosis: preliminary results.
OBJECTIVE The objective of this study was to assess the efficacy of 6-mm Cutting Balloon angioplasty in patients with resistant peripheral stenoses caused by neointimal hyperplasia or irradiation-induced arteriopathy in vascular territories that are not amenable for use of the smaller Cutting Balloons that are used in cardiology. CONCLUSION Peripheral Cutting Balloon angioplasty with the new ...
متن کاملTHERAPY AND PREVENTION AORTITIS Percutaneous transluminal balloon angioplasty of the aorta in patients with aortitis
Four patients with aortitis and stenotic lesions of the aorta were successfully treated by percutaneous transluminal balloon angioplasty. The peak systolic gradient across the constrictions decreased from 82.5 ± 35.7 to 37.5 ± 18.5 mm Hg immediately after dilatation. Repeat angiography in the first three patients performed 2 months later showed a further decrease in the gradient to 13.8 + 9.5 m...
متن کاملDosimetry of 188Re and 186Re sources based on Monte Carlo calculations for endovascular brachytherapy after balloon angioplasty
Background: Recent pre-clinical and clinical studies indicate that irradiation in the dose range of 15 to 30 Gy can reduce rate of restenosis in patients who have undergone an angioplasty. The use of filled balloon with radioactive solution was proposed as one of the possible intravascular irradiation techniques. Materials and Methods: The Monte Carlo N-particle Transport Code (MCNP4b) was used...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
دوره 20 2 شماره
صفحات -