Comparison of the haemostatic properties of conventional monopolar and bipolar transurethral resection of the prostate in patients on oral anticoagulants
نویسندگان
چکیده
INTRODUCTION The aim of study is comparing the haemostatic properties of conventional monopolar resection (TURP) and bipolar transurethral resection in saline (TURIS) of the prostate in patients under chronic oral anticoagulants. MATERIAL AND METHODS Out of a cohort group of 550 endoscopic resections for bladder outlet obstruction, 176 patients on chronic oral anticoagulant therapy required endoscopic resection either by monopolar TURP or bipolar TURIS technology. Changes in haemoglobin, blood transfusion, and clot retention were compared between both groups. RESULTS Mean postoperative change in haemoglobin level was -1.21 ±0.92 mg/dl in the TURP group compared to -1.29 ±0.99 mg/dl in the TURIS group (p = 0.603). The need for blood transfusions and the mean numbers of units transfused did not significantly differ between the 2 groups. Clot retention appeared in 12 patients (15%) in the TURP group compared to 13 patients (13%) in the TURIS group (p = 0.828). CONCLUSIONS Despite promising experimental results of better haemostasis and deeper coagulation depth, bipolar technology does not permit one to reduce the amount of blood loss when compared to patients treated by conventional monopolar technology in this study group of patients on oral anticoagulation therapy. Patients on oral anticoagulants suffer more incidents of clot retention, which sometimes results in re-hospitalisation.
منابع مشابه
Complications and clinical outcome 18 months after bipolar and monopolar transurethral resection of the prostate.
PURPOSE To compare bipolar resection with the conventional monopolar transurethral resection of the prostate (TURP) with respect to peri- and postoperative complications and long-term outcome. PATIENTS AND METHODS Patients with consecutive benign prostatic hyperplasia needing surgery (n=185) from the hospital's waiting list were randomized to TURP using either a bipolar or a monopolar system....
متن کاملBipolar versus monopolar technique for palliative transurethral prostate resection
INTRODUCTION The aim was to evaluate the postoperative morbidity and outcome of palliative endoscopic resections for relief of infravesical obstruction in prostate cancer patients with hormone deprivation therapy, and to investigate the added value of bipolar technology over conventional monopolar resections. MATERIAL AND METHODS A retrospective study was performed on 70 patients with prostat...
متن کاملTransurethral Resection of the Prostate with a Bipolar Tissue Management System Compared to Conventional Monopolar Resectoscope: One-Year Outcome
The purpose of the present study was to evaluate the efficacy and safety of bipolar transurethral prostatectomy (TURP) using the Gyrus PlasmaKinetic System compared with conventional monopolar TURP. This study included 102 patients with benign prostatic hyperplasia (BPH) who underwent TURP from January 2003 to March 2005. In all, 49 consecutive patients had bipolar and 53 had monopolar TURP. Al...
متن کاملTransurethral resection of prostate: a comparison of standard monopolar versus bipolar saline resection.
INTRODUCTION Transurethral resection syndrome is an uncommon but potentially life threatening complication. Various irrigating solutions have been used, normal saline being the most physiological. The recent availability of bipolar cautery has permitted the use of normal saline irrigation. MATERIAL AND METHODS In a randomized prospective study, we compared the safety and efficacy of bipolar c...
متن کاملThe Vista system: a new bipolar resection device for endourological procedures: comparison with conventional resectoscope.
OBJECTIVE Conventional transurethral resection of the prostate (TURP) uses a monopolar electrocautery system in which the current passes from the active electrode through the patient's body towards the return plate and may cause distant negative effects. In this study a new developed resection device, the Vista system, using a bipolar electrocautery system and 0.9% sodium chloride solution for ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2011