Effect of a real-time radiation monitoring device on operator radiation exposure during cardiac catheterization: the radiation reduction during cardiac catheterization using real-time monitoring study.

نویسندگان

  • Georgios Christopoulos
  • Aristotelis C Papayannis
  • Mohammed Alomar
  • Anna Kotsia
  • Tesfaldet T Michael
  • Bavana V Rangan
  • Michele Roesle
  • Deborah Shorrock
  • Lorenza Makke
  • Ronald Layne
  • Rebecca Grabarkewitz
  • Donald Haagen
  • Spyros Maragkoudakis
  • Atif Mohammad
  • Karan Sarode
  • Daisha J Cipher
  • Charles E Chambers
  • Subhash Banerjee
  • Emmanouil S Brilakis
چکیده

BACKGROUND The Radiation Reduction During Cardiac Catheterization Using Real-Time Monitoring study sought to examine the effect of a radiation detection device that provides real-time operator dose reporting through auditory feedback (Bleeper Sv; Vertec Scientific Ltd; Berkshire, UK) on patient dose and operator exposure during cardiac catheterization. METHODS AND RESULTS Between January 2012 and May 2014, 505 patients undergoing coronary angiography, percutaneous coronary intervention, or both were randomized to use (n=253) or no use (n=252) of the Bleeper Sv radiation monitor. Operator radiation exposure was measured in both groups using a second, silent radiation exposure monitoring device. Mean patient age was 65±8 years, most patients (99%) were men, and 30% had prior coronary artery bypass graft surgery. Baseline clinical characteristics were similar in the 2 study groups. Radial access was used in 18% and chronic total occlusion percutaneous coronary intervention constituted 7% of the total procedures. Median procedure time was 17 (12-27) minutes for diagnostic angiography, 42 (28-70) minutes for percutaneous coronary intervention, and 27 (14-51) minutes in the overall study population, with similar distribution between the study groups. First (9 [4-17] versus 14 [7-25] μSv; P<0.001) and second (5 [2-10] versus 7 [4-14] μSv; P<0.001) operator radiation exposure was significantly lower in the Bleeper Sv group. Use of the device did not result in a significant reduction in patient radiation dose. The effect of the Bleeper Sv device on operator radiation exposure was consistent among various study subgroups. CONCLUSIONS Use of a real-time radiation monitoring device that provides auditory feedback can significantly reduce operator radiation exposure during cardiac catheterization. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01510353.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation Dose Reduction during Radial Cardiac Catheterization: Evaluation of a Dedicated Radial Angiography Absorption Shielding Drape

Objectives. Radiation scatter protection shield drapes have been designed with the goal of decreasing radiation dose to the operators during transfemoral catheterization. We sought to investigate the impact on operator radiation exposure of various shielding drapes specifically designed for the radial approach. Background. Radial access for cardiac catheterization has increased due to improved ...

متن کامل

Reduction of operator radiation dose by a pelvic lead shield during cardiac catheterization by radial access: comparison with femoral access.

OBJECTIVES This study sought to determine the efficacy of patient pelvic lead shielding for the reduction of operator radiation exposure during cardiac catheterization via the radial access in comparison with the femoral access. BACKGROUND Cardiac catheterization via the radial access is associated with significantly increased radiation dose to the patient and the operator. Improvements in ra...

متن کامل

Research on reducing radiation exposure during cardiac angiography

Background/Purpose Recent advances in devices involving cardiac catheterization, especially interventional procedures, has lead to increase in examination time and consequent increase in fluoroscopy time and number of filming exposures. Increase in radiation exposure to the patients and the medical personnel has been closed up as a serious agenda. In this study, we focused on the factors that l...

متن کامل

Real-time measurement of radiation exposure to patients during diagnostic coronary angiography and percutaneous interventional procedures.

OBJECTIVES The aim of this study was to accurately assess the radiation exposure received by patients during cardiac catheterization in a large sample representative of the current state of practice in cardiac angiography. BACKGROUND Radiation exposure to patients and laboratory staff has been recognized as a necessary hazard in coronary angiography. The effects on x-ray exposure of the incre...

متن کامل

Fluoroscopy Time during Cardiac Catheterization Procedures Using the Radial and Femoral Routes.

BACKGROUND Use of trans-radial route for cardiac catheterization is on the rise but is associated with increased radiation exposure to the operator. Our aim was to compare the radiation exposure, by taking fluoroscopy time (FT) as a surrogate of radiation exposure, to the operator with femoral and radial routes. METHODS This prospective observational study was carried out at Army Cardiac Cent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 7 6  شماره 

صفحات  -

تاریخ انتشار 2014