Load Control Using Building Thermal Mass

نویسندگان

  • James E. Braun
  • Ray W. Herrick
چکیده

This paper provides an overview of research related to use of building thermal mass for shifting and reducing peak cooling loads in commercial buildings. The paper presents background on the concept and the problem of optimizing zone temperature setpoints and provides specific results that have been obtained through simulations, controlled laboratory testing, and field studies. The studies have demonstrated significant savings potential for use of building thermal mass in commercial buildings. However, the savings are sensitive to many factors, including utility rates, type of equipment, occupancy schedule, building construction, climate conditions, and control strategy. The paper also attempts to provide an assessment of the state of the art in load control using building thermal mass and to identify the steps necessary to achieve widespread application of appropriate control strategies. @DOI: 10.1115/1.1592184#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermal Performance of a Double-pass Solar Air Heater

This study analyzes the thermal performance of solar thermal energy using double-pass absorber plate in Sanandaj, Iran. To this end, a mathematical model was encoded according to the energy and exergy balance equations and solved by MATLAB software. Given the environmental conditions and radiation intensity of a winter day in Sanandaj, the effects of external parameters such as radiation intens...

متن کامل

Development and Application of an Inverse Building Model for Demand Response in Small Commercial Buildings

This paper describes development of an inverse building model and its application in studying the performance of a demand-limiting (DL) control strategy. The demand-limiting strategy involves precooling (PC) a building during unoccupied times, maintaining the zone temperature setpoints at the lower limit of comfort during off-peak, occupied periods, and then limiting the peak cooling rate to a ...

متن کامل

Quantification of Thermal Energy Performance Improvement for Building Integrated Photovoltaic Double-Skin Façade Using Analytical Method

In this research, an analytical method for quantification of the thermal energy performance improvement for a building integrated photovoltaic double-skin façade has provided. The system has been suggested as a retrofit measure for an existing building in Tehran. The effect of thermal performance has been analyzed through computer-assisted developed code using engineering equation solver softwa...

متن کامل

Determination of Optimum Insulation Thickness for Building Walls in Iran Using Life Cycle Cost Analysis

Air-Conditioning (AC) systems are responsible for a considerable portion of the energy consumption in buildings located in high cooling load requiring regions of Iran. In addition, the heat flow through the buildingschr('39') external walls plays a major role in cooling load estimations for the countrychr('39')s hot regions. Therefore, application of insulation materials in external walls has g...

متن کامل

Parameter estimation of internal thermal mass of building dynamic models using genetic algorithm

Building thermal transfer models are essential to predict transient cooling or heating requirements for performance monitoring, diagnosis and control strategy analysis. Detailed physical models are time consuming and often not cost effective. Black box models require a significant amount of training data and may not always reflect the physical behaviors. In this study, a building is described u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003