[Modified DIXON: examination of the different flip angles and echo times for water-fat separation and contrast].

نویسندگان

  • Yasuo Takatsu
  • Takayuki Nakatsuka
  • Tosiaki Miyati
چکیده

The method known as DIXON is imaging from two different echo times (TE), using the opposite phase of water and fat. Modified DIXON (mDIXON) is the method that is calculated from changing the opposing phases 'in' and 'opposed' phases of the actual measurement, to fit the theoretical value. We reviewed that the effect of the water-fat separation and contrast depended on the different flip angles (FA) and echo times (TE). The diluted gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) (from 0 to 5 mmol/l) and liver model was stabilized by lard. In order to measure the SNR and %CV of the lard, the various combinations of TE and FA (from 5 to 20 degrees) were changed. The suitable range for the measurement of the SNR and %CV of the lard, and the contrast of gadolinium Gd-EOB-DTPA and the liver model, in the axial view (including 50% fat), was around the 'opposed' phase in the first TE (TE1) and around the 'in' phase in the second TE (TE2) and FA: 15degrees (TE1: 2.0-2.9 ms, TE2: 4.1-5.0 ms). In order to avoid phase dispersion, shorter TE range is more desirable (TE1: 2.0-2.25 ms, TE2: 4.1-4.5 ms). It is our understanding that the water-fat separation is better in these ranges and under these circumstances, good contrast was obtained.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

Comparing Relative Contrast in Three-dimensional Double-echo Steady State With Routine Sequences for a Better Diagnosis of Knee Cartilage Anomalies

Aims This study compared relative contrast values in three-dimensional Double Echo Steady State (DESS) sequences with two flip angles of 40 and 90 degrees and other routine sequences. The obtained data could help to prove the effects of this sequence, compared to the other routine sequences; accordingly, it could be applied for better detection of lesions resulting from cartilage abnormalities....

متن کامل

CS-Dixon: Compressed Sensing for Water-Fat Dixon Reconstruction

Introduction: Water-fat separation is of interest in several MRI applications including fat suppression and fat quantification. Chemical shift imaging allows robust water-fat separation [1, 2], however the acquisition of multiple images results in prolonged scan time. Accelerated water-fat separation using compressed sensing (CS) was partly addressed in [3] by considering the separation as a sp...

متن کامل

اندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی

Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...

متن کامل

3T Breast MRI using Dixon technique

Introduction: Breast MRI is a highly sensitive imaging tool for the diagnosis and staging of breast cancers. High spatial resolution is a requirement to ensure accurate lesion evaluation, along with fat suppression for assessment of lesion morphology and margins. Active fat suppression such as by chemical shift selective saturation requires homogeneous magnetic field across the entire field-of-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nihon Hoshasen Gijutsu Gakkai zasshi

دوره 68 10  شماره 

صفحات  -

تاریخ انتشار 2012