Depth of electrode insertion and postoperative performance in humans with cochlear implants: a histopathologic study.
نویسندگان
چکیده
The depth of electrode insertion of a multichannel cochlear implant has been suggested as a clinical variable that may correlate with word recognition using the implant. The current study evaluates this relationship using the human temporal bone collection at the Massachusetts Eye and Ear Infirmary. Twenty-seven temporal bones of subjects with cochlear implants were studied. Temporal bones were removed at autopsy, fixed and prepared for histological study by standard techniques. Specimens were then serially sectioned, and reconstructed by two-dimensional methods. Three measures of length were made from each subject's reconstruction: (1) depth of insertion (DI) of the cochlear implant electrode array, from the round window to the array's apical tip; (2) inserted length (IL) from the cochleostomy to the apical tip of the array, and (3) cochlear duct length (CDL) from the round window to the helicotrema. The active electrode length (AEL) was defined as the distance between the most apical and most basal electrodes of the array. Stepwise regression was used to identify whether subsets of six metrics associated with insertion depth (DI, DI/AEL, DI/CDL, IL, IL/AEL and IL/CDL), duration of deafness, sound-processing strategy, potential for central impairment and age at implantation accounted for significant across-subject variance in the last recorded NU-6 word score measured during each subject's life. Age at implantation and potential for central impairment account for significant percentages of the across-subject variance in NU-6 word scores for the 27 subjects studied. None of the insertion metrics accounted for significant performance variance, even when the variance associated with the other variables was controlled. These results, together with those of previous studies, are consistent with a relatively weak association between electrode insertion depth and speech reception.
منابع مشابه
Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan
Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...
متن کاملAcoustic simulations of cochlear implants in human and machine hearing research
In this chapter, we review conventional uses of acoustic simulations in cochlear implants research and introduce novel applications of acoustic simulations of cochlear implants, both in cochlear implants research and in other domains, such as automatic speech recognition (ASR) research. In this respect, the first part of the chapter is dedicated in reviewing the conventional applications of aco...
متن کاملThe histopathology of revision cochlear implantation.
The current study evaluates histopathologic changes in the temporal bones of 4 human subjects who underwent revision cochlear implantation. Specimens were removed at autopsy, fixed and prepared for histological study by standard techniques. Specimens were serially sectioned, reconstructed by two-dimensional methods, and the tracks of the initial and revision cochlear-implant electrodes identifi...
متن کاملSimulating the effect of cochlear-implant electrode insertion depth on speech understanding.
Normally hearing listeners were presented with vowels, consonants, and sentences for identification through an acoustic simulation of a five-channel cochlear implant with electrodes separated by 4 mm (as in the Ineraid implant). The aim of the experiment was to simulate the effect of depth of electrode insertion on identification accuracy. Insertion depth was simulated by outputting sine waves ...
متن کاملPartial deafness cochlear implantation at the University of Kansas: techniques and outcomes.
BACKGROUND One of the most significant recent advances in cochlear implantation is the implantation of patients with residual hearing. These patients have a downsloping sensorineural hearing loss with poor speech discrimination and perform poorly with standard amplification. Studies using a variety of different electrode designs have demonstrated that it is possible to implant an inner ear and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Audiology & neuro-otology
دوره 15 5 شماره
صفحات -
تاریخ انتشار 2010