Risk assessment using single-photon emission computed tomographic technetium-99m sestamibi imaging.

نویسندگان

  • S Iskander
  • A E Iskandrian
چکیده

OBJECTIVES This review summarizes the results of single-photon emission computed tomographic (SPECT) technetium-99m (Tc-99m) tracer imaging in patients with stable symptoms, patients with acute coronary syndromes, patients undergoing major non-cardiac surgery and patients with chest pain in the emergency department. BACKGROUND Previous studies have examined the prognostic value of stress thallium imaging in several subsets of patients with ischemic heart disease. At present, >50% of myocardial perfusion studies are performed with technetium-labeled tracers in the United States. Furthermore, there is a shift from diagnostic to the prognostic utility of stress testing. There are important differences between technetium-labeled tracers and thallium-201. It is therefore important to review the prognostic value of technetium-labeled tracers. METHODS We analyzed published reports in English on risk assessment using Tc-99m perfusion tracers. Results. The largest experience is in patients with stable symptoms, comprising >12,000 patients in 14 studies. In these patients, normal stress SPECT sestamibi images were associated with an average annual hard event rate of 0.6% (death or nonfatal myocardial infarction [MI]). In contrast, patients with abnormal images had a 12-fold higher event rate (7.4% annually). Both fixed and reversible defects are prognostically important, and quantitative analysis shows increased risk in relation to the severity of the abnormality. These results are similar to those obtained with thallium-201. CONCLUSIONS Patients with stable chest pain syndromes and normal stress SPECT sestamibi images have a very low risk of death or nonfatal MI. It is highly unlikely that coronary revascularization can improve survival in such patients. Patients with abnormal images have an intermediate to high risk for future cardiac events, depending on the degree of the abnormality. Further prospective studies comparing aggressive medical therapy with coronary revascularization in these patients are warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prognostic value of dobutamine stress technetium-99m-sestamibi single-photon emission computed tomography myocardial perfusion imaging: stratification of a high-risk population.

OBJECTIVES This work was undertaken to define the intrinsic cardiac risk of the patient population referred for dobutamine stress perfusion imaging and to determine whether dobutamine technetium-99m ((99m)Tc)-sestamibi single-photon emission computed tomography (SPECT) imaging is capable of risk stratification in this population. BACKGROUND In animal models, dobutamine attenuates the myocardi...

متن کامل

Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging.

OBJECTIVES The purpose of this study was to determine how frequently and for what reasons the addition of electrocardiographically gated technetium-99m (Tc-99m) sestamibi single-photon emission computed tomographic (SPECT) images add value to nongated SPECT perfusion images. BACKGROUND Electrocardiographic gating of Tc-99m sestamibi SPECT images permits assessment of regional and global left ...

متن کامل

CLINICAL STUDIES Electrophysiology Right Ventricular Abnormalities Assessed by Myocardial Single-Photon Emission Computed Tomography Using Technetium-99m Sestamibi/Tetrofosmin in Right Ventricle-Originated Ventricular Tachyarrhythmias

OBJECTIVES We sought to determine whether right ventricular (RV) perfusion imaging with technetium99m (Tc-99m) sestamibi or tetrofosmin single-photon emission computed tomography has diagnostic benefit for RV-originated ventricular tachyarrhythmias (RVT). BACKGROUND Identification of RV abnormalities is clinically important to establish RVT etiology. METHODS Forty-seven patients with RVT (23 wi...

متن کامل

Parathyroid scintigraphy in patients with primary hyperparathyroidism: 99mTc sestamibi SPECT and SPECT/CT.

The clinical diagnosis of primary hyperparathyroidism is based largely on serum laboratory test results, as patients often are asymptomatic. Surgery, often with bilateral exploration of the neck, has been considered the definitive treatment for symptomatic disease. However, given that approximately 90% of cases are due to a single parathyroid adenoma, a better treatment may be the selective sur...

متن کامل

Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice.

OBJECTIVES Although transgenic mice have emerged as powerful experimental models of cardiovascular disease, methods for in vivo phenotypic assessment and characterization remain limited, motivating the development of new instruments for biologic measurement. BACKGROUND We have developed a single-photon emission computed tomography system with a pinhole collimator (pinhole SPECT) for high-reso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 32 1  شماره 

صفحات  -

تاریخ انتشار 1998