Real-flair: Real-part Imaging for Fluid Attenuated Inversion Recovery Sequence
نویسندگان
چکیده
Introduction In magnitude-based inversion recovery (IR) imaging, it is sometimes difficult to set optimum inversion time (TI) for nulling target tissue signals. When TI is shorter than the optimum, contrast reductions or dark line artifacts due to wraparound of negative signals are introduced. A real-part imaging for IR (real-IR) [1-5], providing both positive and negative signals, is a solution for those problems and is clinically useful to provide higher contrasts especially for T1W, for brain [3] or myocardium infarction [4-5] than those magnitude-based IR images. Fluid attenuated inversion recovery (FLAIR) imaging is also IR sequence and widely used for brain study. However, real-IR applied to FLAIR sequence has not been reported on. In this study, we applied real-IR technique to Fast-Spin echo (FSE) based interleaved FLAIR sequence [6] and assessed by volunteer brain study. Methods Imaging was performed on Toshiba Excelart Vantage Titan 1.5T and Vantage Titan 3T MRI. Healthy volunteer brain study was performed after obtaining written informed consent. The following parameters were used; 1.5T T2W-FLAIR (T2FLAIR): TR/TE=8000/105 ms, 23 slices, acquisition time=2 min; 1.5T T1W-FLAIR (T1FLAIR): TR/TE=2600/10ms, 17 slices, acquisition time=1 min 43 s. Other common parameters for 1.5T were: 2DFSE, FOV=24 cm, acquisition matrix=192x320 (0.9x0.9x5 mm), slice-thickness=5 mm. Multiple TIs including nulling CSF signals were compared. For spatial phase correction to eliminate background phase, a homodyne-filtering technique [7], subtracting low-frequency phase from the original phase, was employed; the low-pass filter used here was 2D Gaussian linear in k-space, and the FWHM was 5% of the maximum sampling frequency. For evaluations, several tissue contrasts for multiple TI between real and the magnitude, each for T2Wand T1W-FLAIR were compared mainly on 1.5T, and in addition, the possibility of reducing CSF inflow artifacts by real-FLAIR were also assessed. Results and Discussion In comparison between real and magnitude images for T2FLAIR and T1FLAIR (Fig. 1), CSF-soft tissues (GM, WM) contrasts were enhanced on the both real-FLAIR images compared to those corresponding magnitude images; In contrast, GM-WM contrasts at shorter TI from the optimum (nulling CSF signals) were slightly decreased on the T2FLAIR but enhanced on the T1FLAIR in this TI range. In real-FLAIR imaging, recommended TI is set to be shorter than the optimum so as to make the CSF signals negative while keeping contrasts between soft-tissues. It was suitable TI of ~500 ms shorter from the optimum for T1FLAIR as shown by Hou [3], and relatively shorter TI (~300 ms) from the optimum for T2FLAIR. Real-FLAIR is also useful for discriminating low signals region from CSF (Fig. 2) – it is especially likely to be useful for subdural pathology. In addition, CSF inflow effects were reduced by real-FLAIR at shorter TI than the optimum (Fig. 3). This effect was likely due to cancelling CSF signals between negative and positive, respectively from inside and outside of inversion slab. In conclusion, real-FLAIR imaging has more advantageous than the magnitude-base FLAIR imaging from the points of tissue contrast enhancement, robust against TI setting, and reducing CSF inflow artifacts. References: [1] Xiang QS et al. J Magn Reson Imaging 1996;00:775–782; [2] Gowland PA et al. MRM 1991;18:224–231; [3]Hou P et al. AJNR 26:1432–1438, 2005; [4] Kellman P et al. Magn Reson Med 2002;47:372–383; [5] Huber AM. et al. Radiology 2005; 237:854–860; [6] Listerud J et al. Magn Reson Med 1996;6:775–782; [7] Reichenbach JR et al. J Comput Assist Tomogr 2000;24:949–57.
منابع مشابه
The Assessment of Endolymphatic Hydrops with High-resolution 3D Real Inversion Recovery and 3D Fluid Attenuated Inversion Recovery Sequences
Since the initial study by Nakashima et al. [1] who demonstrated that endolymphatic hydrops in patients with Ménière’s disease can be visualized using MR imaging following an intratympanic injection of gadolinium, this topic has gained strong clinical interest internationally [2–13]. The two most common sequences used in the evaluation of endolymphatic hydrops are a 3D Fluid Attenuated Inversio...
متن کاملApplicability and advantages of flow artifact-insensitive fluid-attenuated inversion-recovery MR sequences for imaging the posterior fossa.
We describe a new sequence, flow artifact-insensitive fluid-attenuated inversion recovery (FAIS-FLAIR), that capitalizes on the advantages of fluid-attenuated inversion recovery (FLAIR) while minimizing FLAIR-related artifacts such as those often encountered in the posterior fossa. Twenty-eight patients with posterior fossa disease underwent FAIS-FLAIR, conventional FLAIR, and spin-echo MR stud...
متن کاملMagnetic resonance imaging in partial epilepsy: additional abnormalities shown with the fluid attenuated inversion recovery (FLAIR) pulse sequence.
Thirty six patients with a history of partial epilepsy had MRI of the brain performed with conventional T1 and T2 weighted pulse sequences as well as the fluid attenuated inversion recovery (FLAIR) sequence. Abnormalities were found in 20 cases (56%), in whom there were 25 lesions or groups of lesions. Twenty four of these lesions were more conspicuous with the FLAIR sequence than with any of t...
متن کاملMR of the spine with a fast T1-weighted fluid-attenuated inversion recovery sequence.
PURPOSE To optimize a T1-weighted fast fluid-attenuated inversion recovery (FLAIR) sequence using computer-simulated data and to study its clinical utility for imaging the spine. METHODS Relative signal intensities and contrast of relevant normal and pathologic tissues in the spine were computed using an inversion recovery equation modified to account for a hybrid RARE (rapid acquisition with...
متن کاملT1-weighted fluid-attenuated inversion recovery at low field strength: a viable alternative for T1-weighted intracranial imaging.
BACKGROUND AND PURPOSE T1-weighted spin-echo imaging has been widely used to study anatomic detail and abnormalities of the brain; however, the image contrast of this technique is often poor, especially at low field strengths. We tested a new pulse sequence, T1-weighted fluid-attenuated inversion recovery (FLAIR), which provides good contrast between lesions, surrounding edematous tissue, and n...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010