Comparison of the novel Medtentia double helix mitral annuloplasty system with the Carpentier-Edwards Physio annuloplasty ring: morphological and functional long-term outcome in a mitral valve insufficiency sheep model
نویسندگان
چکیده
BACKGROUND The prevalence of mitral regurgitation in cardiac diseases requires annuloplasty systems that can be implanted without excessive patient burden. This study was designed to examine the morphological and functional outcome of a new double helix mitral annuloplasty ring in an ovine model in comparison to the classical Carpentier-Edwards (CE) annuloplasty ring as measured by reduction of mitral regurgitation and tissue integration. The Medtentia annuloplasty ring (MAR) is a helical device that is rotated into the annulus self-restoring the valve geometry, enabling a faster fixation without the need of elaborate repair of the valve geometry. The ventricular part of the helical ring encircles the valve chords. METHODS Twenty adult sheep were overpaced until 2+ level mitral valve regurgitation was achieved. Seven animals per group received either the MAR or the CE ring. Implantation was performed on-pump in a beating heart through the left atrial appendix. The animals were sacrificed 3.6 ± 0.3 months after surgery following an echocardiography for assessing mitral regurgitation as primary endpoint. The annuloplasty rings with surrounding tissue were harvested for histological analyses as secondary endpoints. The remaining six sheep received the MAR system and were sampled seven, nine or 12 months after surgery. RESULTS Implantation time (p < 0.01) and perfusion time (p < 0.001) as clinical secondary endpoints were significantly shorter in the MAR group. Echocardiography follow-ups showed sufficient valve function repair in nearly all animals with a normalization of the ventricle diameters in both groups (group difference: p = 0.147). The weights of the hearts did not differ significantly. Histology revealed adequately covered atrial annuloplasty rings with functional endothelium and lack of excessive granulation tissue or fibrosis in all specimens. The ventricular projections of the MAR systems encircling the chordae tendineae were not completely covered with neointimal tissue, although in no case were microthrombi detected and no thromboembolic events were recorded. CONCLUSIONS The new MAR system is an easy to use annuloplasty system with a functional outcome comparable to that of the well-proven CE ring. Mitral valve regurgitation is effectively stopped both by restricting the pathological expansion of the annulus and by gathering the chords without thrombus formation.
منابع مشابه
Rigid, complete annuloplasty rings increase anterior mitral leaflet strains in the normal beating ovine heart.
BACKGROUND Annuloplasty ring or band implantation during surgical mitral valve repair perturbs mitral annular dimensions, dynamics, and shape, which have been associated with changes in anterior mitral leaflet (AML) strain patterns and suboptimal long-term repair durability. We hypothesized that rigid rings with nonphysiological three-dimensional shapes, but not saddle-shaped rigid rings or fle...
متن کاملClinical Evaluation of the Physio
Study objectives: Prospective evaluation of a selectively flexible annuloplasty ring was under¬ taken to assess its safety and efficacy. Patients: Between December 1992 and November 1996, 190 patients with mitral regurgitation underwent mitral valve repair using an annuloplasty ring (Carpentier-Edwards Physio; BaxterEdwards CVS Laboratories; Irvine, Calif). Ninety-four were in New York Heart As...
متن کاملHow do annuloplasty rings affect mitral annular strains in the normal beating ovine heart?
BACKGROUND We hypothesized that annuloplasty ring implantation alters mitral annular strains in a normal beating ovine heart preparation. METHODS AND RESULTS Sheep had 16 radiopaque markers sewn equally spaced around the mitral annulus. Edwards Cosgrove partial flexible band (COS; n=12), St Jude complete rigid saddle-shaped annuloplasty ring (RSA; n=10), Carpentier-Edwards Physio (PHY; n=11),...
متن کاملComputer-based comparison of different methods for selecting mitral annuloplasty ring size
BACKGROUND Ring sizing for mitral valve annuloplasty is conventionally done intraoperatively using specific 'sizer' instruments, which are placed onto the valve tissue. This approach is barely reproducible since different sizing strategies have been established among surgeons. The goal of this study is to virtually apply different sizing methods on the basis of pre-repair echocardiography to fi...
متن کاملAnnular height-to-commissural width ratio of annulolasty rings in vivo.
BACKGROUND A "saddle-shaped" mitral annulus with an optimal ratio between annular height and commissural diameter may reduce leaflet and chordal stress and is purported to be conserved across mammalian species. Whether annuloplasty rings maintain this relationship is unknown. METHODS AND RESULTS Twenty-three adult sheep underwent implantation of radiopaque markers on the left ventricle and mi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2013