Balloon embolization during atrial septostomy.
نویسنده
چکیده
SUMMARY The case of an infant with complete transposition is presented. Embolization occurred from a balloon catheter used in performing a Rashkind septostomy. Additional Indexing Words: Oxygenation Renal infarction T HE USE of atrial septostomy as a temporary means of improving systemic oxygenation in infants with transposition of the great vessels was introduced by Rashkind and Miller in 1966.1 Results of this technic have generally been satisfactory, at least on a short-term basis, with few complications other than occasional rupture of the balloon during septostomy.2 The purpose of this paper is to report a case of embolization of a portion of the balloon during atrial septostomy.
منابع مشابه
سپتوستومی دهلیزی با راهنمایی اکوکاردیوگرافی: گزارش هشت بیمار
Background: Balloon atrial septostomy is an emergent procedure in pediatric cardiology. Nowadays, most patients in need of the procedure have acceptable outcomes after surgical repair. Thus, it is important to perform this procedure as safe as possible. By performing early arterial switch operation and prostaglandin infusion, the rate of balloon atrial septostomy has markedly decreased. Howeve...
متن کاملBalloon atrial septostomy under two dimensional echocardiographic control.
Two dimensional echocardiography has been used to guide balloon atrial septostomy in five cases of transposition of the great arteries. A single lumen balloon catheter was used. The catheter can be accurately located within the left atrium before inflation of the balloon, thus avoiding some of the traumatic accidents possible during septostomy. The balloon can be observed creating the atrial de...
متن کاملBalloon atrial septostomy for total anomalous pulmonary venous return.
During the 2-year period July I970 to July I972, balloon atrial septostomy was performed in I2 patients with total anomalous pulmonary venous return, ranging in age from 4 days to I year, and in weight from 2 27 to 6 8o kg. After septostomy, 9 of the I2 patients were improved both clinically and haemodynamically. Of these 9 patients, I died inexplicably I week after the septostomy. In the remai...
متن کاملBalloon atrial septostomy in an infant with tricuspid atresia.
SATO, T., ONOKI, H., KANO I., HORIUCHI BI, T., ISHITOYA, T., ABE, T., ISBIKAWA, S., TANAKA, S. and OKADA, Y . Balloon Atrial Septostomy in an Infant with Tricuspid Atresia. Tohoku J. exp. Med ., 1970, 101 (3), 281-288•\A fivemonth-old female with tricuspid atresia was successfully treated by Rashkind and Miller's balloon septostomy after banding of the pulmonary artery . tricuspid atresia; ball...
متن کاملFate of infants with transposition of the great arteries in relation to balloon atrial septostomy.
The palliation afforded by balloon atrial septostomy to 124 infants with transposition of the great arteries was assessed in terms of survival to 6 months of age without the need for further intervention. Prediction of success or failure in relation to palliation was significantly affected by the presence of associated ventricular septal defect, left ventricular outflow tract obstruction, or pe...