Comparison of late luminal loss response pattern after sirolimus-eluting stent implantation or conventional stenting.

نویسندگان

  • Pedro A Lemos
  • Nestor Mercado
  • Ron T van Domburg
  • Richard E Kuntz
  • William W O'Neill
  • Patrick W Serruys
چکیده

BACKGROUND We investigated the pattern of late luminal loss after sirolimus-eluting or bare stent implantation. METHODS AND RESULTS The study population comprised 238 patients treated with sirolimus-eluting stents and 526 patients treated with conventional stents. The distribution of late loss of sirolimus stents was largely skewed to the right and differed from the distribution for bare stents. When divided according to the presence of binary restenosis (diameter stenosis >50%), restenotic lesions in the bare stent group (26.0%) had a late loss of 1.40+/-0.64 mm and in the sirolimus group (7.9%) of 1.16+/-0.76 mm. Nonrestenotic lesions in the bare stent group had a late loss of 0.58+/-0.44 mm, whereas the late loss of nonrestenotic lesions in the sirolimus group remained close to zero (-0.05+/-0.33 mm). Differences between poststenting and follow-up measurements in the sirolimus group (late loss) resembled variations observed in repeated angiographic measurements, as assessed from a random sample of 30 segments measured repeatedly. After multivariate adjustment, stent type did not influence the degree of late loss in restenotic lesions. However, nonrestenotic bare stents had a significantly larger estimated luminal loss (0.58 mm; 95% CI, 0.52 to 0.65) than sirolimus-eluting stents, for which the predicted late loss was almost 0 (-0.04 mm; 95% CI, -0.10 to 0.02). CONCLUSIONS The pattern of late loss after sirolimus-eluting stent implantation follows a peculiar behavior, different from lesions treated with conventional stents. Whether this is explained by an unusual statistical distribution or a biological all-or-none response of restenosis after sirolimus-eluting stenting remains to be investigated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vascular endothelial growth factor protein levels and gene expression in peripheral monocytes after stenting: a randomized comparative study of sirolimus-eluting and bare-metal stents.

AIMS Although previous studies have indicated that vascular endothelial growth factor (VEGF) plays an important role in the vascular-healing process after stent implantation, its effect on in-stent restenosis is unclear. We assessed VEGF serum protein levels and gene expression in peripheral monocytes in relation to in-stent restenosis after implantation of sirolimus-eluting (SES) and bare meta...

متن کامل

Comparison with conventional therapies of repeated sirolimus-eluting stent implantation for the treatment of drug-eluting coronary stent restenosis.

This study compared the safety and efficacy of repeat percutaneous coronary intervention (PCI) using sirolimus-eluting stents (SESs) with conventional therapies for restenosis after drug-eluting stent placement. Fifty-five consecutive patients with 58 restenotic lesions (31 treated with SESs and 27 treated with paclitaxel-eluting stents) underwent PCI using SESs (33 lesions) or conventional the...

متن کامل

Late stent malapposition after drug-eluting stent implantation: an intravascular ultrasound analysis with long-term follow-up.

BACKGROUND Late stent malapposition (LSM) after drug-eluting stent (DES) implantation has not been evaluated sufficiently in real-world practice. METHODS AND RESULTS We evaluated the incidence, mechanisms, predictors, and long-term prognosis of LSM after DES implantation in 557 patients (705 native lesions; sirolimus-eluting stent in 538 lesions and paclitaxel-eluting stent in 167 lesions) in...

متن کامل

Randomized trial of paclitaxel- and sirolimus-eluting stents in small coronary vessels.

AIMS Sirolimus- and paclitaxel-eluting stents effectively reduce restenosis in small coronary vessels. The relative efficacy of these drug-eluting stents in this high-risk subset is not known. METHODS AND RESULTS A total of 360 patients undergoing percutaneous coronary intervention for de novo lesions in native coronary vessels with a diameter of <2.80 mm received randomly paclitaxel-eluting ...

متن کامل

Two-year angiographic and intravascular ultrasound follow-up after implantation of sirolimus-eluting stents in human coronary arteries.

BACKGROUND The safety and efficacy of sirolimus-eluting stenting have been demonstrated, but the outcome of patients treated with this novel technology beyond the first year remains unknown. We sought to evaluate the angiographic, intravascular ultrasound (IVUS), and clinical outcomes of patients treated with sirolimus-eluting stents 2 years after implantation. METHODS AND RESULTS This study ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 110 20  شماره 

صفحات  -

تاریخ انتشار 2004