Pulmonary deposition of nebulised pentamidine isethionate: effect of nebuliser type, dose, and volume of fill.

نویسندگان

  • M O'Doherty
  • S Thomas
  • C Page
  • C Bradbeer
  • T Nunan
  • N Bateman
چکیده

An estimate of the absolute pulmonary deposition of nebulised pentamidine isethionate was obtained in nine patients with AIDS. Two nebuliser systems were compared, System 22 Mizer (Medic-Aid) and Respirgard II (Marquest), with 50 and 150 mg doses of pentamidine in a 3 ml solution driven by an air flow of 6 l/min with the patient in the sitting position. The 50 mg pentamidine dose was repeated with a 6 ml fill with both devices. The nebuliser cloud was labelled with technetium-99m human serum albumin (Ventocol) and lung deposition was measured with a gamma camera. Of the two nebulisers studied, System 22 Mizer delivered more drug to the lungs as a whole and to each individual lung region, including the peripheral and upper zones. For the 50 mg dose the mean (SEM) total pulmonary deposition with the 3 and the 6 ml fill respectively was 2.63 (0.34) and 3.71 (0.41) mg for the System 22 Mizer and 1.37 (0.26) and 1.45 (0.18) mg for the Respirgard II. For the 150 mg dose the System 22 Mizer delivered 7.16 (1.02) mg and the Respirgard II 4.34 (0.57) mg. Increasing the volume of fill from 3 to 6 ml increased pulmonary deposition with System 22 Mizer, and this was related to an increase in nebuliser output. Neither pulmonary deposition nor nebuliser output was increased by using a 6 ml solution in the Respirgard II. Increasing the volume of fill prolonged the time required for nebulisation with both nebulisers. The System 22 Mizer produced more nonpulmonary (gastric and oropharyngeal) deposition of drug, more frequent local adverse effects (cough, burning in the throat, and a metallic taste), and small reductions in lung function, particularly with the 150 mg pentamidine dose. Thus nebuliser type, volume of fill, and nebuliser dose affect the pulmonary deposition of pentamidine. A 300 mg dose of pentamidine via a Respirgard II is generally recommended as providing effective prophylaxis; our results suggest that similar pulmonary deposition can be produced with System 22 Mizer and 150 mg pentamidine. A clinical trial would be needed to show whether this regimen provides similar prophylactic benefit.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lung deposition of nebulised pentamidine in children.

BACKGROUND Nebulised pentamidine is effective for preventing Pneumocystis carinii pneumonia in adults with acquired immunodeficiency syndrome. The nebuliser dose required to produce equivalent lung concentrations of pentamidine in children is unknown. This study was performed to measure pulmonary pentamidine deposition in children and to relate this to age, ventilation pattern, and body size. ...

متن کامل

Nebulised pentamidine as treatment for Pneumocystis carinii pneumonia in the acquired immunodeficiency syndrome.

Nebulised pentamidine was used to treat 30 patients with Pneumocystis carinii pneumonia. Fourteen patients (group 1) received pentamidine isethionate 4 mg/kg (six patients) or 8 mg/kg (eight patients) via a standard jet nebuliser (Acorn, system 22) with a flow rate of 8 l/min. The aerosol droplets had a mass median aerodynamic diameter of 2.6 microns (geometric standard deviation (GSD) 2.9) and...

متن کامل

Effect of terbutaline on bronchoconstriction induced by nebulised pentamidine.

The severity, duration, and reversibility of pentamidine induced bronchial narrowing was studied with and without pretreatment with nebulised terbutaline 10 mg in an open study of 40 patients seropositive for the human immunodeficiency virus (HIV). All subjects received pentamidine 300 mg in 5 ml water via an Acorn System 22 jet nebuliser. The forced expiratory volume in one second (FEV1) fell ...

متن کامل

Which apparatus for inhaled pentamidine? A comparison of pulmonary deposition via eight nebulisers.

Aerosolised pentamidine 300 mg in 5 or 6 ml solution was administered via 8 different nebuliser systems to 12 patients with acquired immunodeficiency syndrome. Using 99mTc human serum albumin as an indirect marker for pentamidine, pulmonary, extrapulmonary (gastric and oropharyngeal) and alveolar deposition of pentamidine were measured using a gamma camera. Side effects (visual analogue scales)...

متن کامل

Pulmonary deposition of nebulised amiloride in cystic fibrosis: comparison of two nebulisers.

BACKGROUND Preliminary evidence suggests that regular inhalation of nebulised amiloride reduces sputum viscoelasticity, increases the clearance of sputum by mucociliary mechanisms and by coughing and reduces the rate of deterioration in lung function in patients with cystic fibrosis. These effects depend on adequate delivery of amiloride to the airways. This study was performed to quantify and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Thorax

دوره 45 6  شماره 

صفحات  -

تاریخ انتشار 1990