Noninvasive determination of coronary blood flow velocity with cardiovascular magnetic resonance in patients after stent deployment.
نویسندگان
چکیده
BACKGROUND In patients with coronary artery stents, no direct noninvasive coronary artery imaging is possible with magnetic resonance (MR). A well-established method for the assessment of the functional significance of a coronary lesion is the measurement of coronary flow reserve by invasive intracoronary Doppler. The purpose of the study was to determine coronary flow velocity reserve (CFVR) with MR after stent deployment. METHODS AND RESULTS Thirty-eight patients after successful PTCA and stent deployment were included. CFVR was measured perpendicular to the artery distal to the stent using phase-contrast velocity quantification at rest and during adenosine-stimulated hyperemia with a 1.5T MR tomograph (ACS NT, Philips). Measurements were repeated after 3 months and compared with invasive coronary angiography. In 18 patients, additional invasive Doppler flow measurements were obtained. CFVR could be determined in 29 of 38 (76%) of the patients. After 3 months, significant differences were obtained between coronary arteries with and without restenosis. Using a threshold of 1.2, a sensitivity of 83% with a specificity of 94% was achieved for > or =75% stenoses. CFVR with CMR was similar to Doppler results (r=0.87), with a mean relative difference of 7.5%. CONCLUSIONS In patients with preserved coronary microcirculating vasoreactivity that are suitable for MR coronary angiography and flow assessments, CMR measures of coronary blood flow velocities reserve may be used to detect in-stent restenosis.
منابع مشابه
Assessment of coronary flow velocity reserve using fast velocity-encoded cine MRI for noninvasive detection of restenosis after coronary stent implantation.
PURPOSE Serial change of the coronary flow velocity reserve was evaluated with fast velocity-encoded cine magnetic resonance imaging (MRI) for noninvasive detection of restenosis after coronary stent implantation. METHOD In total, 60 MRI flow studies were performed in 10 patients with coronary artery disease who undersvent elective successful stent implantation to the lesion in the proximal l...
متن کاملBlood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method
Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...
متن کاملCoronary flow evaluation by TIMI frame count and magnetic resonance flow velocity in patients with coronary artery ectasia.
PURPOSE Coronary artery ectasia (CAE) is defined as a dilatation of an arterial segment to a diameter at least 1.5 times that of the adjacent artery. It is characterized by slow flow, predisposing to thrombosis. The TIMI frame count (TFC) technique has been successfully used for the assessment of coronary flow velocity using coronary angiograms (CA). Our aim was to compare TFC with magnetic res...
متن کاملRelation between the assessment of microvascular injury by cardiovascular magnetic resonance and coronary Doppler flow velocity measurements in patients with acute anterior wall myocardial infarction.
OBJECTIVES We studied the relation between presence and severity of microvascular obstruction (MO), measured by cardiovascular magnetic resonance (CMR) and intracoronary Doppler flow measurements, for assessment of myocardial reperfusion in patients with acute anterior myocardial infarction (MI) treated by primary percutaneous coronary intervention (PCI). BACKGROUND Cardiovascular magnetic re...
متن کاملSimultaneous noninvasive measurement of blood flow in the great cardiac vein and left anterior descending artery.
Magnetic resonance (MR) flow mapping can be used to quantify flow velocity and volume flow in the coronary vessels noninvasively. The close anatomic relationship of the left anterior descending artery (LAD) with the great cardiac vein (GCV) allows imaging of both in one view. We examined the feasibility to discriminate between these two vessels based on the flow pattern and to measure the flow ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 107 13 شماره
صفحات -
تاریخ انتشار 2003