Modified Integral Counting Method with Various Quenched Samples for Different Scintillators
نویسندگان
چکیده
A modified integral counting method (MICM) with various quenched samples (MICM-VQ) has been investigated for its applicability for different scintillators using b emitters, C and S. To assess the influence of scintillators, three sets of C quenched standards and two S cocktail series were prepared. Two sets of C quenched standards were used for the toluene-compatible scintillator, the other for the Ultima GoldTM scintillator. Sulfur-35 cocktail series were prepared with either EcoscintTM XR or Ultima GoldTM AB. The radioactivity of these samples was determined using the MICM-VQ, with the results conforming to assayed values. Hence the MICM-VQ can assay the radioactivity of sample cocktails with various scintillators and requires no standard sample.
منابع مشابه
The Effect of Quench on Quantitating Alpha Radionuclides by Liquid Scintillation Counting
Detecting and quantitating alpha emitting radionuclides are routine tasks in nuclear energy and environmental monitoring. For this purpose, liquid scintillation counting (LSC) is an excellent method because alphas are counted with nearly 100% counting efficiency with low backgrounds, even with severe quenching. Quenching agents such as inorganic acids, organic acids, and extractive scintillator...
متن کاملThe Effect of Quench on Quantitating Alpha Radionuclides by Liquid Scintillation Counting
Detecting and quantitating alpha emitting radionuclides are routine tasks in nuclear energy and environmental monitoring. For this purpose, liquid scintillation counting (LSC) is an excellent method because alphas are counted with nearly 100% counting efficiency with low backgrounds, even with severe quenching. Quenching agents such as inorganic acids, organic acids, and extractive scintillator...
متن کاملOptimized Method for Reticulocyte Counting: Simple, Accurate, and Comparable to Flow Cytometry
Background: Reticulocytes are immature red blood cells with RNA, spending the final stages of their maturation in the peripheral blood. The number of reticulocytes in the peripheral blood is the salient evidence of the effectiveness of bone marrow to produce red blood cells. Currently, reticulocyte count is done manually or automatically in clinical laboratories. Difficulties and limitations of...
متن کاملRadioactive contamination of scintillators
Low counting experiments (search for double β decay and dark matter particles, measurements of neutrino fluxes from different sources, search for hypothetical nuclear and subnuclear processes, low background α, β, γ spectrometry) require extremely low background of a detector. Scintillators are widely used to search for rare events both as conventional scintillation detectors and as cryogenic s...
متن کاملOptimization of measurement counting time in Gamma-ray spectrometry of soil samples
The method of optimal measurement counting time in Gamma spectrometry for soil samples was studied. Gamma spectrometry was done based on minimum detectable activity using the HPGe- p type with efficiency of 30% and FWHM 1.7keV (for 1.33 MeV 60Co). The samples were IAEA-RG Th-1, IAEA-RGU-1 and IAEA-RGK-1 prepared in bottles. The measurements were done for 12 different counting times from 5 min t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -