Reliability of Glutamate Quantification in Human Nucleus Accumbens Using Proton Magnetic Resonance Spectroscopy at a 70-cm Wide-Bore Clinical 3T MRI System

نویسندگان

  • Xi-Long Liu
  • Long Li
  • Jian-Neng Li
  • Jia-Hui Rong
  • Bo Liu
  • Ze-Xuan Hu
چکیده

The human nucleus accumbens is a challenging region to study using proton magnetic resonance spectroscopy (1H-MRS) on a 70-cm wide-bore clinical 3T MRI system. The aim of this study was to investigate the reliability for quantitative measurement of glutamate concentration in the nucleus accumbens using a 70-cm wide-bore clinical 3T MRI. 1H-MRS of the nucleus accumbens was acquired using the Point-Resolved Spectroscopic Sequence (PRESS) with echo time of 40 ms from 10 healthy volunteers (5 female; age range: 18-30 years) on two separate visits (a baseline, and 1-month time point). The Java-based Magnetic Resonance User Interface (jMRUI) software package was used to quantitatively measure the absolute metabolite concentrations. The test-retest reliability and reproducibility were assessed using intraclass correlations coefficients (ICC), and coefficients of variation (CV). Glutamate concentrations were similar across visits (P = 0.832). Reproducibility measures for all metabolites were good with CV ranging from 7.8 to 14.0%. The ICC values of all metabolites for the intra-class measures were excellent (ICC > 0.8), except that the reliability for Glx (glutamate + glutamine) was good (ICC = 0.768). Pearson correlations for all metabolites were all highly significant (r = 0.636-0.788, P < 0.05). In conclusion, the short-echo-time PRESS can reliably obtain high quality glutamate spectrum from a ~3.4 cm3 voxel of the nucleus accumbens using a 70-cm wide-bore clinical 3T MRI.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Geometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes

Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...

متن کامل

In vivo metabolite differences between the basal ganglia and cerebellum of the rat brain detected with proton MRS at 3T.

In vivo magnetic resonance spectroscopy (MRS) enables non-invasive longitudinal tracking of brain chemistry changes that can accompany aging, neurodegenerative disease, drug addiction and experimental manipulations in animals modeling such conditions. J-coupled resonances, such as glutamate, which are highly relevant to neuropsychiatric conditions are difficult to resolve on a clinical 3T MR sc...

متن کامل

Quantification of Glutamate and Glutamine using CT-PRESS at 3T

Introduction Glutamate (Glu) and glutamine (Gln) are two major neurochemicals in the central nervous system. Quantifying Glu and Gln in vivo using magnetic resonance spectroscopy (MRS) has been of particular interest to basic science for understanding the Glu/Gln component of the Krebs cycle and its alteration by neuropsychiatric disorders such as Alzheimer’s disease, epilepsy and alcoholism. H...

متن کامل

1H NMR spectroscopy of rat brain in vivo at 14.1Tesla: improvements in quantification of the neurochemical profile.

Ultra-short echo-time proton single voxel spectra of rat brain were obtained on a 14.1T 26 cm horizontal bore system. At this field, the fitted linewidth in the brain tissue of adult rats was about 11 Hz. New, separated resonances ascribed to phosphocholine, glycerophosphocholine and N-acetylaspartate were detected for the first time in vivo in the spectral range of 4.2-4.4 ppm. Moreover, impro...

متن کامل

T1 and T2 Metabolite Relaxation Times in Normal Brain at 3T and 7T

Proton magnetic resonance spectroscopy (MRS) is a powerful noninvasive tool that has been widely used for the assessment of brain metabolites and the investigation of normal and abnormal metabolism in brain tissue. With the availability of improved hardware and acquisition techniques, in vivo single-voxel 1H-MRS and multivoxel magnetic resonance spectroscopic imaging (MRSI) can offer new possib...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017