Tomographic imaging of micrometer-sized optical and soft-x-ray beams.

نویسندگان

  • H M Hertz
  • R L Byer
چکیده

The knife-edge technique for measurements of micrometer-sized beams is extended to two-dimensional imaging by tomographic reconstruction of multiangular knife-edge data. Two-dimensional intensity distributions at optical (633-nm) and soft-x-ray (13.5-nm) wavelengths at the focal region of a Schwarzschild objective are presented. The resolution is limited by the 200-nm step size used in the data acquisition.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of reaction parameters on crystal phase growth and optical properties of ultrasonic assisted hydro- and solvothermal synthesized sub-micrometer-sized CdS spheres

Sub-micrometer-sized CdS spheres were synthesized by hydrothermal and solvothermal reactions using Cd(NO3)2.4H2O and CH4N2S raw materials at a constant stoichiometric 1 : 2, Cd : S molar ratio. Various conditions such as solvent type (water and/or ethanol), reaction time and temperature were examined for the synthesis of the targets. The sy...

متن کامل

Influence of reaction parameters on crystal phase growth and optical properties of ultrasonic assisted hydro- and solvothermal synthesized sub-micrometer-sized CdS spheres

Sub-micrometer-sized CdS spheres were synthesized by hydrothermal and solvothermal reactions using Cd(NO3)2.4H2O and CH4N2S raw materials at a constant stoichiometric 1 : 2, Cd : S molar ratio. Various conditions such as solvent type (water and/or ethanol), reaction time and temperature were examined for the synthesis of the targets. The sy...

متن کامل

Hard X-ray Phase-Contrast Tomographic Nanoimaging

Synchrotron‐based full‐field tomographic microscopy established itself as a tool for noninvasive investigations. Many beamlines worldwide routinely achieve micrometer spatial resolution while the isotropic 100‐nm barrier is reached and trespassed only by few instruments, mainly in the soft x‐ray regime. We present an x‐ray, full‐field microscope with tomographic capabilities operating at 10 keV...

متن کامل

Perfect Crystals in the Asymmetric Bragg Geometry as Optical Elements for Coherent X-ray Beams.

Perfect crystals in the asymmetric Bragg geometry are evaluated as optical elements for manipulating coherent X-ray beams. Such optics can be used to modify the transverse coherence length of a synchrotron X-ray beam, with the intention of increasing the usable coherent flux. The wavelength range, angular divergence and flux of X-rays passing through a pinhole aperture are examined in detail, a...

متن کامل

Optimal signal-to-noise ratios for soft x-ray lensless imaging.

We propose and demonstrate a method to gauge and optimize the signal-to-noise ratios (SNRs) in lensless imaging using partially coherent sources. Through spatial filtering we tuned the coherence width of an incoherent soft x-ray undulator source, and we deduce that there exists an optimal spatial filter setting for imaging micrometer-sized objects, while high-resolution imaging is best executed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 15 7  شماره 

صفحات  -

تاریخ انتشار 1990