Evaluation of stable retentive properties of overdenture attachments.

نویسندگان

  • Vygandas Rutkunas
  • Hiroshi Mizutani
  • Hidekazu Takahashi
چکیده

OBJECTIVES To evaluate fatigue of stud (ERA Overdenture (orange and white), Locator Root (pink) and OP anchor # 4) and magnetic (Magfit EX600W) attachments by measuring maximum retentive force. To compare retentive force of overdenture attachments after their reach stable retention. To determine minimum number of cycles required to reach stable retention. MATERIAL AND METHODS Three specimens of each type of attachment were used. Micromaterial testing machine (MMT-250NB-10, Shimadzu Co., Tokyo, Japan) with a sensor interface PCD-320 and software package PCD-30A (Kyowa Electronic Instruments Co., Tokyo, Japan) was used to performe 2000 insertion-removal cycles with 50 mm/min cross head speed. Maximum retentive force was measured initially and after each 40 cycles. STATISTICAL ANALYSIS paired-samples t-test, one-way ANOVA and Scheffe post-hoc tests (P<0.05). RESULTS Before and after fatigue simulation statistically significant differences existed among the five types of attachments. Decrease of retention was characteristic for all attachments except OP. After fatigue LRP was most retentive. Magnetic attachments preserved maximum amount of retention measured at the baseline (98%). EO and EW attachments have preserved only 25% and 37% of initial retention respectively. CONCLUSIONS Due to fatigue overdenture attachments gradually loose their retention. Stud attachments are more susceptible to fatigue than magnets. Eight hundred cycles are required to achieve relatively stable retention of overdenture attachments.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retention of maxillary implant overdenture bars of different designs.

STATEMENT OF PROBLEM The specific degree of retention for overdenture attachments is unknown in relation to design, location, and alignment to supporting dental implants. PURPOSE The purpose of this study was to evaluate the initial retention characteristics of 5 implant maxillary overdenture designs under in vitro dislodging forces. MATERIAL AND METHODS A simulated edentulous maxilla was f...

متن کامل

An in vitro comparative study to evaluate the retention of different attachment systems used in implant-retained overdentures

AIM The aim of this in vitro study was to compare the change in the retentive force and removal torque of three attachment systems during simulation of insertion-removal cycles. METHODOLOGY Edentulous mandibular models were made with heat-cured polymethyl methacrylate resin. Two implant replicas (CMI), of 3.75 mm diameter and 10 mm length, were placed in the intraforaminal region. Acrylic res...

متن کامل

Maximum dislodging forces of implant overdenture stud attachments.

PURPOSE The aim of this study was to compare the retention and stability of the Nobel Biocare standard ball (NBS), Nobel Biocare 2.25-mm-diameter ball (NB2), Zest Anchor (ZA), Zest Anchor Advanced Generation (ZAAG), Sterngold ERA orange (SEO), and Sterngold ERA white (SEW) attachments on an implant-retained overdenture model. MATERIALS AND METHODS The attachments were tested using 2 permanent...

متن کامل

Orientation of retentive matrices on spherical attachments independent of implant parallelism.

Traditionally, it has been advocated that implants planned for use as overdenture abutments be placed parallel to each other to obtain predictable attachment retention and complete seating of the restoration and to prevent premature wear of components. However, it is often difficult or impossible to place implants parallel to each other, and patients with implants that have already been placed ...

متن کامل

The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture

PURPOSE The aim of this study was to compare the retention of mini implant overdenture by the number, the type of magnetic attachment, and the directions of applied dislodging force. MATERIALS AND METHODS The experimental groups were designed by the number and type of magnetic attachment. Twenty samples were tested with Magden implants. Each attachment was composed of the magnet assembly in o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stomatologija

دوره 7 4  شماره 

صفحات  -

تاریخ انتشار 2005