Validation of quantitative magnetic resonance imaging-based apparent bone volume fraction in peri-articular tibial bone of cadaveric knees
نویسندگان
چکیده
BACKGROUND In the knee, high-resolution magnetic resonance (MR) imaging has demonstrated that increased apparent bone volume fraction (trabecular bone volume per total volume; BV/TV) in the peri-articular proximal medial tibia is associated with joint space narrowing and the presence of bone marrow lesions. However, despite evidence of construct validity, MR-based apparent BV/TV has not yet been cross-validated in the proximal medial tibia by comparison with a gold standard (e.g., micro-computed tomography [microCT]). In this cadaveric validation study we explored the association between MR-based apparent BV/TV and microCT-based BV/TV in the proximal peri-articular medial tibia. METHODS Fresh cadaveric whole knee specimens were obtained from individuals 51 to 80 years of age with no knee pathology other than osteoarthritis. Ten knees were collected from five cadavers within 10 hours of death and underwent a 3-Tesla MR exam including a coronal-oblique 3-dimensional fast imaging with steady state precession (3D FISP) sequence within 36 hours of death. The specimens were placed in a 4% paraformaldehyde in phosphate buffer within 58 hours of death. After preservation, a subchondral region from the tibial plateau was collected and underwent microCT imaging with a voxel size of 9 μm x 9 μm x 9 μm. A single reader analyzed the microCT images in a similar volume of interest as selected in the MR measures. A different reader analyzed the MR-based trabecular morphometry using a custom analysis tool. To analyze the MR-based trabecular morphometry, a rectangular region of interest (ROI) was positioned on the 20 central images in the proximal medial tibial subchondral bone. The primary outcome measures were MR-based and microCT-based trabecular BV/TV in the proximal medial tibia. RESULTS The MR-based apparent BV/TV was strongly correlated with microCT-based BV/TV (r=0.83, confidence interval=0.42 to 0.96), despite the MR-based apparent BV/TV being systematically lower than measured using microCT. CONCLUSIONS MR-based apparent BV/TV in the proximal peri-articular medial tibia has good construct validity and may represent an alternative for CT-based BV/TV.
منابع مشابه
Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging
Background: Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which leads to knee joint stability. Posterior tibial slope affects flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the...
متن کاملCorrelation of Anthropometric Measurements of Proximal Tibia in Iranian Knees with Size of Current Tibial Implants
of the Caucasian population. The purpose of this study was to investigate the morphometry of the proximal tibia in thestandard resected surface of total knee arthroplasty (TKA).Methods: In this descriptive study, the anthropometric data of the proximal tibia were measured in 132 knees (80 malesand 52 females) using magnetic resonance imaging in 2015. The collected data include...
متن کاملKnee cartilage topography, thickness, and contact areas from MRI: in-vitro calibration and in-vivo measurements.
OBJECTIVE This study assessed the three-dimensional accuracy of magnetic resonance imaging (MRI) for measuring articular surface topographies and cartilage thicknesses of human cadaveric knee joints, by comparison with the calibrated stereophotogrammetric (SPG) method. METHODS Six fresh frozen cadaveric knees and the knees of four volunteers were imaged with a three-dimensional spoiled gradie...
متن کاملAccuracy of high-resolution in vivo micro magnetic resonance imaging for measurements of microstructural and mechanical properties of human distal tibial bone.
Micro magnetic resonance imaging (µMRI) is an in vivo imaging method that permits 3D quantification of cortical and trabecular bone microstructure. µMR images can also be used for building microstructural finite element (µFE) models to assess bone stiffness, which highly correlates with bone's resistance to fractures. In order for µMRI-based microstructural and µFE analyses to become standard c...
متن کاملPotential role of the posterior cruciate ligament synovio-entheseal complex in joint effusion in early osteoarthritis: a magnetic resonance imaging and histological evaluation of cadaveric tissue and data from the Osteoarthritis Initiative
OBJECTIVE This study explored posterior cruciate ligament (PCL) synovio-entheseal complex (SEC) microanatomy to determine whether it may participate in the early osteoarthritis (OA) disease process. METHODS SEC microanatomy and OA features were evaluated in 14 non-arthritic cadaveric knees (mean age = 69.9) using magnetic resonance imaging (MRI) and histology. MRI images of 49 subjects select...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2014