Geometric error of cervical point A calculated through traditional reconstruction procedures for brachytherapy treatment

نویسندگان

  • Liyun Chang
  • Sheng‐Yow Ho
  • Shyh‐An Yeh
  • Tsair‐Fwu Lee
  • Pang‐Yu Chen
چکیده

Brachytherapy used in local cervical cancer is still widely based on 2D standard dose planning with the prescription to point A, which is invisible on imaging and located at a high-dose gradient. In this study, the geometric location error of point A was investigated. It is traditionally reconstructed in the treatment planning system after carefully digitizing the point marks that were previously drawn on the orthogonal radiographs into the system. Two Cartesian coordinates of point A were established and compared. One was built up based on the geometric definition of point A and would be taken as the true coordinate, while the other was built up through traditional clinical treatment procedures and named as the practical coordinate. The orthogonal-film reconstruction technique was used and the location error between the practical and the true coordinate introduced from the variations of, first, the angle between the tandem and the simulator gantry-rotation-axis, and second, the interval between the tandem flange and the simulator isocenter, was analyzed. The location error of point A was higher if the tandem was rotated away from the gantry-rotation-axis or if the location of the tandem flange was set away from the isocenter. If a tandem with a 30-degree curvature was rotated away from the gantry-rotation-axis 10 degrees in the anterior-posterior (AP) view, and there was an 8.7 cm interval between the flange and the isocenter, the location error of point A would be greater than 3 mm without including other errors from simulator calibration, data input, patient setup and movements. To reduce the location error of point A calculated for traditional reconstruction procedures, it is suggested to move the couch or patient to make the mid-point of two points A near the isocenter and the tandem in the AP view parallel to the gantry-rotation-axis as much as possible.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An innovative method to acquire the location of point A for cervical cancer treatment by HDR brachytherapy

Brachytherapy of local cervical cancer is generally accomplished through film-based treatment planning with the prescription directed to point A, which is invisible on images and is located at a high-dose gradient area. Through a standard reconstruction method by digitizing film points, the location error for point A would be 3mm with a condition of 30° curvature tandem, which is 10° away from ...

متن کامل

Rectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector

Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...

متن کامل

Comparison the treatment time of cobalt and iridium sources in HDR brachytherapy

Introduction: The use of long-half-life Cobalt source instead of iridium source will be very helpful in HDR brachytherapy for treatment of cervical cancer. The aim of this study was compared the treatment time with cobalt and iridium source in brachytherapy for treatment of cervical cancer using Tandem-ovoid applicator. Materials and Methods: In this study, 19...

متن کامل

Out-Of-Field Dose Measurement and Second Cancer-Risk Estimation Following External Beam Radiotherapy and Brachytherapy for Cervical Cancer Treatment: A Phantom Study

Introduction: The present study aimed to measure the scatter and leakage dose received by out-of-field organs while delivering Radiotherapy (RT) treatment of cervical cancer. Moreover, this study estimated the risk of second cancer (SC). The doses to out-of-field organs were measured using a lithium fluoride (TLD 100) dosimeter while delivering External Beam Radiothera...

متن کامل

A comparative study of two reconstructive methods and different recommendations in intracavitary brachytherapy

PURPOSE Intracavitary brachytherapy (ICB) is a widely used technique in the treatment of cervical cancer. In our Institute, we use different reconstructive methods in the conventional planning procedure. The main aim of this study was to compare these methods using critical organ doses obtained in various treatment plans. There is a small difference in the recommendations in selecting bladder d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015