Microcomputed tomography provides high accuracy congenital heart disease diagnosis in neonatal and fetal mice.

نویسندگان

  • Andrew J Kim
  • Richard Francis
  • Xiaoqin Liu
  • William A Devine
  • Ricardo Ramirez
  • Shane J Anderton
  • Li Yin Wong
  • Fahim Faruque
  • George C Gabriel
  • Wendy Chung
  • Linda Leatherbury
  • Kimimasa Tobita
  • Cecilia W Lo
چکیده

BACKGROUND Mice are well suited for modeling human congenital heart disease (CHD), given their 4-chamber cardiac anatomy. However, mice with CHD invariably die prenatally/neonatally, causing CHD phenotypes to be missed. Therefore, we investigated the efficacy of noninvasive microcomputed tomography (micro-CT) to screen for CHD in stillborn/fetal mice. These studies were performed using chemically mutagenized mice expected to be enriched for birth defects, including CHD. METHODS AND RESULTS Stillborn/fetal mice obtained from the breeding of N-ethyl-N-nitrosourea mutagenized mice were formalin-fixed and stained with iodine, then micro-CT scanned. Those diagnosed with CHD and some CHD-negative pups were necropsied. A subset of these were further analyzed by histopathology to confirm the CHD/no-CHD diagnosis. Micro-CT scanning of 2105 fetal/newborn mice revealed an abundance of ventricular septal defects (n=307). Overall, we observed an accuracy of 89.8% for ventricular septal defect diagnosis. Outflow tract anomalies identified by micro-CT included double outlet right ventricle (n=36), transposition of the great arteries (n=14), and persistent truncus arteriosus (n=3). These were diagnosed with a 97.4% accuracy. Aortic arch anomalies also were readily detected with an overall 99.6% accuracy. This included right aortic arch (n=28) and coarctation/interrupted aortic arch (n=12). Also detected by micro-CT were atrioventricular septal defects (n=22), tricuspid hypoplasia/atresia (n=13), and coronary artery fistulas (n=16). They yielded accuracies of 98.9%, 100%, and 97.8%, respectively. CONCLUSIONS Contrast enhanced micro-CT imaging in neonatal/fetal mice can reliably detect a wide spectrum of CHD. We conclude that micro-CT imaging can be used for routine rapid assessments of structural heart defects in fetal/newborn mice.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the frequency and causes of heart consulting in patients admitted to the neonatal intensive care unit

Background: Congenital heart diseases are the second group of congenital anomalies in infants. These disorders are a major cause of death in the first year of a child's life. Early detection helps to treat these diseases better. In this study cardiology consultations of hospitalized infants in the neonatal intensive care unit were evaluated. Methods: In this cross-sectional study, two hundred ...

متن کامل

گزارش یک مورد سندرم لوپوس نوزادی

Neonatal lupus syndrome is a rare disease. The manifestations of this disease in neonatal period include congenital heart block, cutaneous leasions, liver disease, thrombocytopenia, Neutropenia, pulmonary and nurologic derangements. Most of the clinical manifestations ofter disappear spontaneously. Although congenital heart block is usually permanent, and often require pacemakers. Congenital he...

متن کامل

Fetal cardiac screening: why bother?

Congenital heart disease (CHD) is a common form of congenital malformation associated with significant morbidity and mortality. Antenatal diagnosis of life-threatening forms of CHD may help to improve survival and morbidity as well as allowing parental choice and preparation. The diagnosis of CHD during fetal life can be made with a very high level of diagnostic accuracy in tertiary centres dea...

متن کامل

Multimodal imaging reveals a role for Akt1 in fetal cardiac development

Even though congenital heart disease is the most prevalent malformation, little is known about how mutations affect cardiovascular function during development. Akt1 is a crucial intracellular signaling molecule, affecting cell survival, proliferation, and metabolism. The aim of this study was to determine the role of Akt1 on prenatal cardiac development. In utero echocardiography was performed ...

متن کامل

Presentation of congenital heart disease in infancy: implications for routine examination.

AIM To investigate the performance of routine neonatal and 6 week examinations for detecting congenital heart disease. METHODS A retrospective review of findings on clinical examination was conducted of a cohort of live born infants with congenital heart disease in one health region in 1987-94. RESULTS Of 1590 babies with congenital heart disease, 523 (33%) presented before neonatal examina...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 2013