Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography.

نویسندگان

  • Kian Keong Poh
  • Robert A Levine
  • Jorge Solis
  • Liang Shen
  • Mary Flaherty
  • Yue-Jian Kang
  • J Luis Guerrero
  • Judy Hung
چکیده

AIMS Two-dimensional echocardiographic (2DE) continuity-equation derived aortic valve area (AVA) in aortic stenosis (AS) relies on non-simultaneous measurement of left ventricular outflow tract (LVOT) velocity and geometric assumptions of LVOT area, which can amplify error, especially in upper septal hypertrophy (USH). We hypothesized that real-time three-dimensional echocardiography (RT3DE) can improve accuracy of AVA by directly measuring LVOT stroke volume (SV) in one window. METHODS AND RESULTS RT3DE colour Doppler and 2DE were acquired in 68 AS patients (74 +/- 12 yrs) prospectively. SV was derived from flow obtained from a sampling curve placed orthogonal to LVOT (Tomtec Imaging). Agreement between continuity-equation derived AVA by RT3DE (AVA(3D-SV)) and 2DE (AVA(2D)) and predictors of discrepancies were analysed. Validation of LVOT SV was performed by aortic flow probe in a sheep model with balloon inflation of septum to mimic USH. There was only modest correlation between AVA(2D) and AVA(3D-SV) (r = 0.71, difference 0.11 +/- 0.23 cm(2)). The degree of USH was significantly associated with difference in AVA calculation (r = 0.4, P = 0.005). In experimentally distorted LVOT geometry in sheep, RT3DE correlated better with flow probe assessment (r = 0.96, P < 0.001) than 2DE (r = 0.71, P = 0.006). CONCLUSION RT3DE colour Doppler-derived LVOT SV in the calculation of AVA by continuity equation is more accurate than 2D, including in situations such as USH, common in the elderly, which modify LVOT geometry.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative Analysis of Aortic Valve Stenosis and Aortic Root Dimensions by Three-Dimensional Echocardiography in Patients Scheduled for Transcutaneous Aortic Valve Implantation

Accurate assessment of the aortic valve area (AVA) and evaluation of the aortic root are important for clinical decision-making in patients being considered for transcatheter aortic valve implantation (TAVI). Real-time three-dimensional transesophageal echocardiography (RT3D-TEE) provides accurate and reliable quantitative assessment of aortic valve stenosis and the aortic root. We performed tw...

متن کامل

Severe aortic valve stenosis with low-gradient and preserved ejection fraction: a misclassification issue?

INTRODUCTION AND OBJECTIVES Low-gradient severe aortic stenosis with preserved ejection fraction is a controversial entity. Misclassification of valvulopathy severity could explain the inconsistencies reported in the prognosis of these patients. Planimetry of the aortic area using three-dimensional transesophageal echocardiography could clear up these doubts. The objectives were to assess the a...

متن کامل

Planimetry of aortic valve area using multiplane transoesophageal echocardiography is not a reliable method for assessing severity of aortic stenosis.

OBJECTIVE To assess the reliability of aortic valve area planimetry by multiplane transoesophageal echocardiography (TOE) in aortic stenosis. DESIGN Study of the diagnostic value of aortic valve area planimetry using multiplane TOE, compared with catheterisation and the continuity equation, both being considered as criterion standards. SETTING University hospital. PATIENTS 49 consecutive ...

متن کامل

Comparison of Doppler echocardiographic methods with heart catheterisation in assessing aortic valve area in 100 patients with aortic stenosis.

OBJECTIVE To examine the practicability and accuracy of Doppler echocardiographic methods in determining aortic valve area. METHODS Aortic valve areas determined by three methods using Doppler echocardiography (applying the continuity equation and the modified Gorlin formula using data from Doppler echocardiography and right heart catheterisation) were compared with values obtained by heart c...

متن کامل

VALVULAR HEART DISEASE A hybrid approach for quantification of aortic valve stenosis using cardiac magnetic resonance imaging and echocardiography

Background. Doppler-derived calculation of aortic valve area (AVA) using the continuity equation can be difficult at times, e.g. due to poor acoustic windows, heavy calcification of the aortic valve, or significant flow acceleration in the left ventricular outflow tract. The aim of this study was to compare AVA as assessed by means of transthoracic echocardiography (TTE) with a hybrid approach,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European heart journal

دوره 29 20  شماره 

صفحات  -

تاریخ انتشار 2008