Modulated repetition time look-locker (MORTLL): a method for rapid high resolution three-dimensional T1 mapping.

نویسندگان

  • Neville D Gai
  • John A Butman
چکیده

PURPOSE To demonstrate a modification of the Look-Locker (LL) technique that enables rapid high resolution T1 mapping over the physiologic range of intracranial T1 values, ranging from white matter to cerebrospinal fluid (CSF). This is achieved by use of a three-dimensional (3D) balanced steady-state free precession (b-SSFP) acquisition (for high signal-to-noise and resolution) along with variable repetition time to allow effective full recovery of longitudinal magnetization. MATERIALS AND METHODS Two modifications to the Look-Locker technique were made to realize high resolution imaging in a clinically reasonable scan time. The 3D b-SSFP acquisition after an initial inversion pulse was followed by a variable repetition time. This technique makes it possible to image a volume of thin contiguous slices with high resolution and accuracy using a simple fitting procedure and is particularly useful for imaging long T1 species such as CSF. The total scan time is directly proportional to the number of slices to be acquired. The scan time was reduced by almost half when the repetition time was modified using a predesigned smooth function. Phantoms and volunteers were imaged at different resolutions on a 3 Tesla scanner. Results were compared with other accepted techniques. RESULTS T1 values in the brain corresponded well with full repetition time imaging as well as inversion recovery spin echo imaging. T1 values for white matter, gray matter, and CSF were measured to be 755 +/- 10 ms, 1202 +/- 9 ms, and 4482 +/- 71 ms, respectively. Scan times were reduced by approximately half over full repetition time measurements. CONCLUSION High resolution T1 maps can be obtained rapidly and with a relatively simple postprocessing method. The technique is particularly well suited for long T1 species. For example, changes in the composition of proteins in CSF are linked to various pathologies. The T1 values showed excellent agreement with values obtained from inversion recovery spin-echo imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid T1 mapping of mouse myocardium with saturation recovery Look-Locker method.

Dynamic contrast-enhanced MRI using gadolinium or manganese provides unique characterization of myocardium and its pathology. In this study, an electrocardiography (ECG) triggered saturation recovery Look-Locker method was developed and validated for fast cardiac T(1) mapping in small animal models. By sampling the initial portion of the longitudinal magnetization recovery curve, high temporal ...

متن کامل

Optimization of Look-Locker Turbo-Field Echo-Planar Imaging and Evaluation of Its Accuracy in Head and Neck 3D T1 Mapping

PURPOSE We present a sequence for T1 relaxation-time mapping that enables a rapid and accurate measuring. The sequence is based on the Look-Locker method by employing turbo-field echo-planar imaging (TFEPI) acquisitions and time to free relaxation after constant application of the radiofrequency (RF) pulses. We optimized the sequence, and then evaluated the accuracy of the method in imaging of ...

متن کامل

Correction for T1 Determined Using Rapid Look-Locker b-SSFP and a Simple Two Parameter Model Fit

Introduction: Multiple acquisitions along the longitudinal magnetization curve as done with the Look-Locker (LL) technique perturbs the inversion recovery curve. The b-SSFP sequence perturbs magnetization minimally compared to other sequences [1]. However, when inversion recovery is incomplete (if TRseq<5T1max) or the flip angle is relatively large (>10° for GM/WM/CSF mapping), a three paramete...

متن کامل

Free-breathing post-contrast three-dimensional T1 mapping: Volumetric assessment of myocardial T1 values.

PURPOSE To develop a three-dimensional (3D) free-breathing myocardial T1 mapping sequence for assessment of left ventricle diffuse fibrosis after contrast administration. METHODS In the proposed sequence, multiple 3D inversion recovery images are acquired in an interleaved manner. A mixed prospective/retrospective navigator scheme is used to obtain the 3D Cartesian k-space data with fully sam...

متن کامل

Fast high-resolution T1 mapping using inversion-recovery Look-Locker echo-planar imaging at steady state: optimization for accuracy and reliability.

A fast T(1) measurement sequence using inversion recovery Look-Locker echo-planar imaging at steady state (IR LL-EPI SS) is presented. Delay time for a full magnetization recovery is not required in the sequence, saving acquisition time significantly for high-resolution T(1) mapping. Imaging parameters of the IR LL-EPI SS sequence were optimized to minimize the bias from the excitation pulses i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 30 3  شماره 

صفحات  -

تاریخ انتشار 2009