Determination of reference values for optical properties of liquid phantoms based on Intralipid and India ink.

نویسندگان

  • L Spinelli
  • M Botwicz
  • N Zolek
  • M Kacprzak
  • D Milej
  • P Sawosz
  • A Liebert
  • U Weigel
  • T Durduran
  • F Foschum
  • A Kienle
  • F Baribeau
  • S Leclair
  • J-P Bouchard
  • I Noiseux
  • P Gallant
  • O Mermut
  • A Farina
  • A Pifferi
  • A Torricelli
  • R Cubeddu
  • H-C Ho
  • M Mazurenka
  • H Wabnitz
  • K Klauenberg
  • O Bodnar
  • C Elster
  • M Bénazech-Lavoué
  • Y Bérubé-Lauzière
  • F Lesage
  • D Khoptyar
  • A A Subash
  • S Andersson-Engels
  • P Di Ninni
  • F Martelli
  • G Zaccanti
چکیده

A multi-center study has been set up to accurately characterize the optical properties of diffusive liquid phantoms based on Intralipid and India ink at near-infrared (NIR) wavelengths. Nine research laboratories from six countries adopting different measurement techniques, instrumental set-ups, and data analysis methods determined at their best the optical properties and relative uncertainties of diffusive dilutions prepared with common samples of the two compounds. By exploiting a suitable statistical model, comprehensive reference values at three NIR wavelengths for the intrinsic absorption coefficient of India ink and the intrinsic reduced scattering coefficient of Intralipid-20% were determined with an uncertainty of about 2% or better, depending on the wavelength considered, and 1%, respectively. Even if in this study we focused on particular batches of India ink and Intralipid, the reference values determined here represent a solid and useful starting point for preparing diffusive liquid phantoms with accurately defined optical properties. Furthermore, due to the ready availability, low cost, long-term stability and batch-to-batch reproducibility of these compounds, they provide a unique fundamental tool for the calibration and performance assessment of diffuse optical spectroscopy instrumentation intended to be used in laboratory or clinical environment. Finally, the collaborative work presented here demonstrates that the accuracy level attained in this work for optical properties of diffusive phantoms is reliable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of dependent scattering on the optical properties of Intralipid tissue phantoms

The calibration of optical tissue-simulating phantoms remains an open question in spite of the many techniques proposed for accurate measurements of optical properties. As a consequence, a reference phantom with well known optical properties is still missing. As a first step towards a reference phantom we have recently proposed to use dilutions of Intralipid 20%. In this paper we discuss a matt...

متن کامل

Frequency-modulated light scattering interferometry employed for optical properties and dynamics studies of turbid media

In the present work, fiber-based frequency-modulated light scattering interferometry (FMLSI) is developed and employed for studies of optical properties and dynamics in liquid phantoms made from Intralipid(®). The fiber-based FMLSI system retrieves the optical properties by examining the intensity fluctuations through the turbid medium in a heterodyne detection scheme using a continuous-wave fr...

متن کامل

Tissue-mimicking phantoms for photoacoustic and ultrasonic imaging

In both photoacoustic (PA) and ultrasonic (US) imaging, overall image quality is influenced by the optical and acoustical properties of the medium. Consequently, with the increased use of combined PA and US (PAUS) imaging in preclinical and clinical applications, the ability to provide phantoms that are capable of mimicking desired properties of soft tissues is critical. To this end, gelatin-ba...

متن کامل

Computationally effective solution of the inverse problem in time-of-flight spectroscopy.

Photon time-of-flight (PTOF) spectroscopy enables the estimation of absorption and reduced scattering coefficients of turbid media by measuring the propagation time of short light pulses through turbid medium. The present investigation provides a comparison of the assessed absorption and reduced scattering coefficients from PTOF measurements of intralipid 20% and India ink-based optical phantom...

متن کامل

Performance assessment of time-domain optical brain imagers, part 2: nEUROPt protocol.

The nEUROPt protocol is one of two new protocols developed within the European project nEUROPt to characterize the performances of time-domain systems for optical imaging of the brain. It was applied in joint measurement campaigns to compare the various instruments and to assess the impact of technical improvements. This protocol addresses the characteristic of optical brain imaging to detect, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biomedical optics express

دوره 5 7  شماره 

صفحات  -