Heparin-coated stent placement for the treatment of stenoses in small coronary arteries of symptomatic patients.

نویسندگان

  • Michael Haude
  • Thomas F M Konorza
  • Uldis Kalnins
  • Andrejs Erglis
  • Kari Saunamäki
  • Helmut D Glogar
  • Eberhard Grube
  • Robert Gil
  • Antonio Serra
  • Hans G Richardt
  • Peter Sick
  • Raimund Erbel
چکیده

BACKGROUND The role of stents, especially of heparin-coated stents for the treatment of stenoses in small coronary arteries, is still unclear. Therefore, we performed this prospective, randomized trial to evaluate the angiographic and clinical outcome after treatment of stenoses in small coronary arteries (2.0 to 2.6 mm) of symptomatic patients. METHODS AND RESULTS We randomly assigned 588 patients to angioplasty (n=195), bare stenting (n=196), or heparin-coated stenting (n=197). The primary end point was minimal lumen diameter (MLD) at 6 months. With comparable baseline parameters, the two stent arms showed a larger postinterventional MLD, larger acute gain, and smaller residual percent diameter stenosis, although a residual stenosis of 12+/-16% was achieved in the angioplasty arm, including a 27% crossover rate to stenting. Eighty percent of patients had follow-up angiography, which documented a borderline significantly larger MLD and smaller percent diameter stenosis for the two stent groups (1.34+/-0.48 mm and 42+/-20% after angioplasty, 1.47+/-0.48 mm and 36+/-20% after bare stenting, and 1.45+/-0.54 mm and 38+/-23% after heparin-coated stenting; P=0.049 and P=0.038, respectively), but restenosis rates were not different (32%, 25%, and 30%). Thrombotic events occurred in 1.0% after angioplasty and 0.5% after bare or heparin-coated stenting. Survival without myocardial infarction or target vessel revascularization at 250 days was 84.6% (angioplasty), 88.3% (bare stenting), and 88.3% (heparin-coated stenting; log-rank P=0.39). CONCLUSION Compared with angioplasty with provisional stenting, bare and heparin-coated stenting confer superior angiographic results and a nonsignificant 24% reduction in clinical events, with no difference between bare and heparin-coated stenting in the treatment of stenoses in small coronary arteries.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety, Efficacy and Clinical Outcome of Direct Stent Implantation

Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...

متن کامل

Stenting in small coronary arteries (SISCA) trial. A randomized comparison between balloon angioplasty and the heparin-coated beStent.

OBJECTIVES The purpose of this study was to assess the clinical and angiographic benefits of elective stenting in coronary arteries with a reference diameter of 2.1 to 3.0 mm, as compared with traditional percutaneous transluminal coronary angioplasty (PTCA). BACKGROUND The problems related to small-vessel stenting might be overcome using modern stents designed for small vessels, combined wit...

متن کامل

Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent

Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...

متن کامل

Wingspan stents for the treatment of symptomatic atherosclerotic stenosis in small intracranial vessels: safety and efficacy evaluation.

BACKGROUND AND PURPOSE Until now, endovascular treatment of symptomatic atherosclerotic stenosis in small intracranial arteries (≤2.5 mm) was limited. We evaluated the safety and efficacy of the treatment by using Wingspan stents in arteries of this caliber. MATERIALS AND METHODS From March 2007 to July 2010, 53 symptomatic intracranial stenoses with narrowing of at least 50% in 53 patients w...

متن کامل

An advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries

Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 107 9  شماره 

صفحات  -

تاریخ انتشار 2003