The pulmonary artery catheter: when and why it should be used.

نویسنده

  • B A Finegan
چکیده

The pulmonary artery catheter (PAC) has been in widespread clinical use for 20 yr. It has been modified to allow measurement of cardiac output (CO), mixed venous oxygen saturation (Sf, O2), right ventficular ejection fraction (RVEF) and temporary pacing. The indications for insertion of a PAC have multiplied with time, as has the controversy over the contribution (or lack thereof) of the PAC to improving patient outcome. In order to define the role of PAC monitoring in one's practice it is essential to understand both the limitations of PAC-derived information, and the potential risks and benefits associated with using a PAC.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary artery catheter-induced hemorrhage.

Pulmonary artery rupture by a flow-directed balloon-tipped catheter is a rare complication if guidelines for insertion of catheters are strictly applied. It should be stressed that the need for a "confirmed" wedge pressure should be weighed against the very real risk of this potentially fatal complication. Users of this catheter should expect and anticipate distal migration of the catheter tip....

متن کامل

Review of recommendations to prevent and reduce catheter-related bloodstream infections

ABSTRACT Aim. We sought to review studies regarding interventions to prevent or reduce catheter-related bloodstream infections (CRBSIs). Background. CRBSIs are associated with peripheral and central intravenous catheters, including nontunneled central catheters, tunneled central catheters, peripherally inserted central venous catheters (PICC), totally implanted intravascular access devices (por...

متن کامل

Pulmonary artery catheter knotting in a coronary artery bypass surgery patient.

A fifty seven years old female patient came to operating room for coronary artery bypass grafting (CABG) surgery. After induction, invasive monitoring lines were placed. Pulmonary artery catheter (PAC) floated after three attempts and it was wedged at 60cm. Intra operative course was smooth and patient transferred to cardiac intensive care unit (CICU). First chest X-ray revealed PAC knotting in...

متن کامل

Cardiovascular monitoring in sepsis: why pulmonary artery catheters should not be used.

Crit Care Resuscitation ISSN: 1441-2772 4 September 2006 8 3 256-259 © C r i t C a r e R es u s c i t a t i on 20 06 www.jficm.anzca.edu.au/aaccm/journal/publications.htm Pro–con debate monary artery catheter (PAC). It was introduced practice in the 1970s, and enthusiastically ta intensive care physicians who assumed that measurements and derived values it provided direct therapy in a way that ...

متن کامل

C Current use of the pulmonary artery catheter Greenberg

Current Opinion in Critical Care 2009, 15:249–253 Purpose of review The pulmonary artery catheter is one of the most scrutinized monitors used in intensive care today. Pulmonary artery catheter use is declining due to limited demonstrated beneficial outcomes and the advancement of less invasive monitoring. This study discusses the current use of the pulmonary artery catheter and problems associ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Canadian journal of anaesthesia = Journal canadien d'anesthesie

دوره 39 5 Pt 2  شماره 

صفحات  -

تاریخ انتشار 1992