Potentiometric determination of cysteine with thiol sensitive silver-mercury electrode.

نویسندگان

  • Ryszard Drozdz
  • Jerzy Naskalski
  • Anna Zabek-Adamska
چکیده

A potentiometric procedure for cysteine thiol group concentration monitoring in media generating free radicals was developed using a thiol specific silver-mercury electrode. Electrolytic deposition of mercury on a silver wire and treatment with 20 mM cysteine in 0.5 M NaOH were used to produce the electrode. A silver-chloride electrode in saturated KCl was the reference. A glass capillary with 1 M KNO3 in 1% agarose gel was the liquid junction. The electrode responded to cysteine concentration in the range from 0.01 to 20 mM yielding a perfect linear relationship for the dependence of log [cysteine] versus electrode potential [mV], with b0 (constant) = -373.43 [mV], b1 (slope) = -53.82 and correlation coefficient r2 = 0.97. The electrode potential change per decade of cysteine concentration was 57 mV. The minimal measurable signal response was at a cysteine concentration of 0.01 mM. The signal CV amounted to 4-6% for cysteine concentrations of 0.01 to 0.05 mM and to less than 1% for cysteine concentrations of 0.5 to 20 mM. The response time ranged from about 100 s for cysteine concentrations of 0.01 to 0.1 mM to 30 s at higher cysteine concentrations. The standard curve reproducibility was the best at cysteine concentrations from 0.1 to 20 mM. In a reaction medium containing cysteine and copper(II)-histidine complex ([His-Cu]2+) solution in 55 mM phosphate buffer pH 7.4 the electrode adequately responded to changes in cysteine concentration. Beside cysteine, the silver-mercury electrode responded also to thiol groups of homocysteine and glutathione, however, the Nernst equation slope was about half of that for cysteine.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of trace amounts of Ag (I) in waste water samples by a novel potentiometric sensor based on perphenazine as an ionophore

Background and Objective: Silver is a toxic heavy metal that is used in various industries and has adverse effects on both human health and the environment. In this respect its determination with sensitive and economic analytical methods is of great importance. Materials and Methods: In this research, a novel ion selective electrode based on perphenazine as an ionophore was developed for deter...

متن کامل

Determination of Strontium Ion in Depilatory Powder, Toothpaste, and Raticide Samples using a Novel and Highly Sensitive Potentiometric Sensor Coupled with a Central Composite Design

The strontium ion, in water-soluble forms, is one of the major pollutant in drinking water. Therefore, a simple, rapid, selective, and sensitive potentiometric carbon paste electrode was developed to measure strontium ion in real samples with complex matrices. To prepare the potentiometric sensor, a synthetic ligand ((E)-4-(((2-amino-4-chlorophenyl)imino)methyl)-5-(hydroxymethyl)-2-methyl pyrid...

متن کامل

High-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

متن کامل

Ormosil Encapsulated Pyrroloquinoline Quinone-Modified Electrochemical Sensor for Thiols

An organically modified sol-gel glass (ORMOSIL) encapsulating pyrroloquinoline quinone (PQQ)-modified electrode for the rapid, sensitive and simple determination of thiol-containing compounds such as cysteine and glutathione is reported. The effect of applied potential, nature of thiol compound and pH on the response of the sensor was examined and optimum conditions were determined. The electro...

متن کامل

Indirect potentiometric titration of sulphamethoxazole in the presence of trimethoprim in co-trimazole tablets using copper based mercury film electrode.

A simple and rapid indirect potentiometric titration of sulphamethoxazole in the presence of trimethoprim contained in co-trimazole tablets is described. The method is based on the formation of a complex of sulphamethoxazole with a known excess of silver ions and the titration of unreacted silver ion potentiometrically using an inexpensive lab-made copper based mercury film electrode (CBMFE). T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta biochimica Polonica

دوره 54 1  شماره 

صفحات  -

تاریخ انتشار 2007