Linear least-squares method for unbiased estimation of T1 from SPGR signals.

نویسندگان

  • Lin-Ching Chang
  • Cheng Guan Koay
  • Peter J Basser
  • Carlo Pierpaoli
چکیده

The longitudinal relaxation time, T(1), can be estimated from two or more spoiled gradient recalled echo images (SPGR) acquired with different flip angles and/or repetition times (TRs). The function relating signal intensity to flip angle and TR is nonlinear; however, a linear form proposed 30 years ago is currently widely used. Here we show that this linear method provides T(1) estimates that have similar precision but lower accuracy than those obtained with a nonlinear method. We also show that T(1) estimated by the linear method is biased due to improper accounting for noise in the fitting. This bias can be significant for clinical SPGR images; for example, T(1) estimated in brain tissue (800 ms < T(1) < 1600 ms) can be overestimated by 10% to 20%. We propose a weighting scheme that correctly accounts for the noise contribution in the fitting procedure. Monte Carlo simulations of SPGR experiments are used to evaluate the accuracy of the estimated T(1) from the widely-used linear, the proposed weighted-uncertainty linear, and the nonlinear methods. We show that the linear method with weighted uncertainties reduces the bias of the linear method, providing T(1) estimates comparable in precision and accuracy to those of the nonlinear method while reducing computation time significantly.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Linear and Non-linear Fitting Methods for Estimating T1 from SPGR Signals

Introduction: T1 maps can be computed from spoiled gradient recalled echo (SPGR) images acquired with different repetition times (TRs) and/or flip angles. Recently, the acquisition of high resolution T1 maps in a clinically feasible timeframe has been demonstrated with Driven Equilibrium Single Pulse Observation of T1 (DESPOT1) [1]. DESPOT1 derives T1 from two or more SPGR images acquired with ...

متن کامل

Accurate Estimation of T1 from SPGR Signals

Introduction T1 maps can be computed from spoiled gradient recalled echo (SPGR) images acquired with different flip angles and/or repetition times (TRs). The function relating signal intensity to flip angle and TR is non-linear; however, a linear form proposed by Gupta in 1977 [1] is currently widely used [1-6]. Using this linearized model, T1 has been estimated with a linear least squares (LLS...

متن کامل

MR Estimation of Longitudinal Relaxation Time (T1) in Spoiled Gradient Echo Using an Adaptive Neural Network

Introduction: The acquisition of high-resolution T1 maps in a clinically feasible time frame has been demonstrated with Driven Equilibrium Single Pulse Observation of T1 (DESPOT1) [1-3]. DESPOT1 derives the longitudinal relaxation time, T1, from two or more spoiled gradient recalled echo (SPGR) images acquired with a constant TR and different flip angles [2, 3]. In general, T1 can be estimated ...

متن کامل

An Optimal Framework for T1 Estimation in an SPGR Acquisition

INTRODUCTION The longitudinal relaxation time, T1, and the magnetization at thermal equilibrium, M0, can be estimated from two or more spoiled gradient recalled echo (SPGR) images acquired with different flip angles and/or repetition times (TR) [1-5]. To date, several approaches have been proposed for selecting the combination of number of data points, flip angles, and TR values that would prov...

متن کامل

Spoiling properties of the VAFI method for fast simultaneous T1 and B1 mapping from actual flip-angle imaging (AFI) and variable flip-angle (VFA) data

ntroduction: Accurate measurements of both T1 and flip angle (FA) are important to many quantitative imaging applications. The use of steady-state sequences offers a fast way to acquire 3D volumetric maps of these parameters, and the recently proposed combined fitting of variable flip angle (VFA) [1] and actual flip-angle imaging (AFI) [2] data (VAFI) has been shown to be highly accurate and ef...